probleM

cause

solution

1. Low/Slow Production

Low Water Pressure

Assure a minimum of 40psi incoming water pressure. 

Watts sells a booster pump if home water pressure is low. 

Make sure water supply is turned on and Adapt-A-Valve™ is 

all the way open.

Crimps in tubing

Check tubing and straighten or replace as necessary.

Clogged pre-filters

Replace pre-filters.

Fouled membrane

Replace membrane and flow restrictor.

2. Milky colored Water

Air in system

Air in the system is a normal occurrence with initial start up 

of the RO system. This milky look will disappear during normal 

use within 1-2 weeks. If condition reoccurs after filter change, 

drain tank 1 to 2 times.

3. Water constantly running, unit will not shut off

Low water pressure

See #1 above

Crimp in supply tube

Check tubing and straighten or repair as necessary.

High water pressure

Check incoming water pressure to make sure it does not 

exceed 80psi. A pressure relief valve may be necessary.

High pressure in Tank

Empty storage tank of water. Set tank air pressure between 

5-7psi. See page 7.

Low Pressure in Tank

Use a Digital Air Gauge for best results. The empty tank pres-

sure should be 5-7psi. See Page 7.

4.  Noise / Water from faucet vent hole or noise from in drain 

line drain. 

Crimp or restriction

Check tubing and straighten or repair as necessary. 

Straighten all drain lines. Clear blockage. Cut off any excess 

tubing.

Drain tube clogged

Caused from dishwasher or garbage disposal. 

Disconnect the 

3

8

" black line at the drain, clean the 

3

8

" black 

line out with a wire, then reconnect. Blowing air through the 

line will not always remove the clog.

5. Small amount of water in storage tank

System starting up

Normally it takes 4-6 hours to fill tank. Note: low incoming 

water pressure and/or temperature can drastically reduce 

production rate.

Low water pressure

See #1 above.

To much air in tank

Tank air pressure should be 5-7psi when empty of water. 

If below 5psi add air or bleed if above 7psi. 

Check only when tank is empty of water. See Page 7.

6. Water leaks from the blue or white filter housing

Not properly tightened

Tighten the bowl.

Kinked O-ring

Turn off the water supply and release the pressure. 

Replace the O-ring if necessary. Then lubricate it and make 

sure the O-ring is seated in the filter bowl properly before 

reinstalling the filter bowl.

7. Low water flow from faucet

Check air pressure in tank

Use a Digital Air Gauge for best results. The empty tank pres-

sure should be 5-7psi. See Page 7.

 Troubleshooting

Summary of Contents for PWSYS-RO-KC4 Kwik-Change

Page 1: ... Valve Installation 5 Drain Saddle Installation 6 Black 3 8 Tube Connection From The Faucet To The Drain Saddle 6 Green Tube Connection From RO Module To The Adapt A Valve 6 Reverse Osmosis Module Mounting 6 Red Tube Connection From The Faucet To The Flow Restrictor 6 Check Air Pressure in the Tank 7 Tank Ball Valve Installation 7 Blue Tube Connection From RO Module To The Tank 7 Blue Tube Connect...

Page 2: ...hat cause bad taste and odor are greatly reduced Stage 3 Membrane recommended change 2 5 years Stage 3 is the heart of the reverse osmosis system the RO membrane This semi permeable membrane will ef fectively take out TDS Sodium and heavy metals such as arsenic copper and lead as well as Cysts such as Giar dia and cryptosporidium Because the process of making this high quality drinking water takes...

Page 3: ... filters that can be used if copper tubing fol lows the Reverse Osmosis unit Be sure to follow any state province or local regulations during installation Drill a Hole for the Faucet in a Porcelain Sink Note Most sinks are predrilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer or soap dispenser see Step 2 Caution Porcelain sinks are extre...

Page 4: ...dges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a perma nent leak proof seal Pull on the tube to check that it is secure It is a good practice to test the system prior to le...

Page 5: ...to the faucet base until it is fully seated Turn the handle up away from you to the OFF position Step D Connect the loose end of the 3 8 blue plastic tubing from the faucet to the 1 4 x 3 8 plastic reducing union Connect the 1 4 blue tubing from the OUTLET SIDE of the filtration unit to the 1 4 side of the union Minimum Maximum Mounting Hole Size 1 11 4 Torque on Toggle Bolt 5 lb in max Adapt A Va...

Page 6: ...ine and if there is any bend or dip in the tube the rinse water will not flow into the drain properly Water may back up and come out the air gap hole in the back of the faucet Step A With the drain saddle secured onto the drain pipe using a 1 4 drill bit installed in your electric drill insert the drill bit through the opening in the drain saddle and drill through the drain pipe Caution It is very...

Page 7: ...e allowed to fill up fully in order for the ice maker system to work properly Step B Open the RO faucet and leave it open until water begins to trickle out It will come out slowly Step C After water trickles out of the faucet close the RO faucet allowing the storage tank to fill with water It may take 4 to 6 hours to fill the tank completely depending on the pro duction capability of the membrane ...

Page 8: ... Repeat this procedure for the 2nd filter cartridges When finished flush your tank completely once to remove any natural carbon fines from the RO system Check over the next 24 hours to ensure no leaks are present 6 Month System Maintenance Annual Maintenance Order filter by calling Watts at 1 800 224 1299 Item Needed 7100117 Includes 1 Sediment Filter 1 Membrane 1 Carbon Block Filter 1 Final In Li...

Page 9: ...sumer confidence report If you have your own well you will need to have the water evaluated The local health department or the state environmental health agency can provide a list of test kits or certified labs There are two forms of arsenic pentavalent arsenic also called As V As 5 and trivalent arsenic also called As III As 3 In well water arsenic may be pentavalent trivalent or a combination of...

Page 10: ...e should be 5 7psi See Page 7 4 Noise Water from faucet vent hole or noise from in drain line drain Crimp or restriction Check tubing and straighten or repair as necessary Straighten all drain lines Clear blockage Cut off any excess tubing Drain tube clogged Caused from dishwasher or garbage disposal Disconnect the 3 8 black line at the drain clean the 3 8 black line out with a wire then reconnect...

Page 11: ... 8 BLACK TUBE DRAIN 8 3 SEDIMENT FILTER 4 PRE CARBON FILTER 5 RO MEMBRANE 6 POST CARBON FILTER 7 17 16 18 1 4 x 1 4 UNION 19 14 ITEM EDP DESCRIPTION 1 7300068 Adapt A Valve 2 7300070 Automatic Shut Off Valve 1 4 QC 3 7100469 Sediment Filter 4 7100109 Carbon Filter 5 7100125 Reverse Osmosis Membrane 6 7100462 Post Carbon Filter 7 7300034 Elbow 1 4 QC X 1 4 Stem 8 7100174 Storage Tank 3 Gal White 9 ...

Page 12: ...edies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT...

Reviews: