background image

Installation, Operation  
and Maintenance Manual

Model PWSCAB30K
Water Softeners

IOM-WQ-PWSCAB30K

Important

Please read the entire manual before proceeding with the  

installation and startup. Your failure to follow any attached 

instructions or operating parameters may lead to the product’s 

failure.
Save manual for future reference

Refer to enclosed for operating parameters to ensure proper use 

with your water supply.

Table of Contents 

Pages

How To Get the Maximum Efficiency From Your Appliance  . . . . . . . . . 2
Checklist Before Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Do’s and Don’ts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Reference Illustrations   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Installation and Start-Up Procedures  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Setting the Controller    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Parts Diagrams   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Softener Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Warranty Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

PWSCAB30K

PURE WATER

Note:

 Do not use with water that is microbiologically unsafe or 

of unknown quality without adequate disinfection before or after 

the system. 

Summary of Contents for PWSCAB30K Pure Water

Page 1: ...ed for operating parameters to ensure proper use with your water supply Table of Contents Pages How To Get the Maximum Efficiency From Your Appliance 2 Checklist Before Installation 2 Do s and Don ts...

Page 2: ...ed to verify that your appliance is right for the job See Page 4 3 Water Supply Flow Rate 5 gallons per minute is recommended as minimum 4 Drain Drain appliance to floor drain or washer drain To preve...

Page 3: ...s Valves To simplify installation and servicing a one piece or a three way by pass valve system is recommended when installing your appliance A bypass system also provides access to untreated water wh...

Page 4: ...here is a threaded connection to facilitate repairing a potential leak in one of your soldered joints 3 To prevent heat damage to the plastic pipe threads of the adapter prepare the copper tail assemb...

Page 5: ...5 Reference Illustrations Figure 7 Figure 8 Plugging In Transformer Do not plug transformer into an outlet that is controlled by on off switch Adding Salt To The Brine Cabinet Figure 9...

Page 6: ...lve in the Service position See Figure 6 6 Connect Overflow Line The overflow line is used to direct excess water to a floor drain if the brine tank fills with too much water or the appliance malfunct...

Page 7: ...ut ton and hold for 3 seconds The REGENERATE button is used when starting your water conditioner to start an immediate regeneration or to restore capacity if you have run out of salt If your appliance...

Page 8: ...s Pressing and releasing the SET button will advance programming to the next step 6 If Gallons was chosen 12 is now displayed If Liters was chosen 24 is displayed Pressing and releasing the CHANGE but...

Page 9: ...9 Controller Layout Figure 10...

Page 10: ...abinet Figure 11 Item Description QTY 1 Valve Cover Assembly 1 2 Salt Port Cover 1 3 12 Volt Transformer Power Cord 1 4 Cabinet 1 5 2 Piece Overflow 1 6 Brine Tubing 3 8 18 7 Support Panel 1 8 Compute...

Page 11: ...Adapter Assembly 1 2 3 4 I O Adapter O ring 2 3 Resin Tank Assembly empty 1 4 End Cap O ring 2 5 Drive End Cap Assembly w o motor magnet disc 1 6 Screw 4 7 O ring Small End Cap 1 8 Injector Assembly...

Page 12: ...The gasket seals at its outer edges and between the inlet screen and nozzle opening These areas must be free of defects such as tears or pits and be free of debris 4 Injector Nozzle 1 Creates the vac...

Page 13: ...ontroller The three wire assembly connecting the black wafer Hall Effect Sensor or the Controller board must not be severely bent folded over cut or broken Care should be taken when putting the Sensor...

Page 14: ...Cap When assembling the Drain End Cap to the Main Valve Body care should be taken to make sure the small O ring is aligned with the opening in the Main Valve Body and that the large O ring stays in th...

Page 15: ...alve retainer 5 push in and turn clockwise to unlock the retainer CAUTION Do not attempt to remove the retainer with the piston assembly in place This will damage the housing and or the retainer Push...

Page 16: ...ession nuts are tight 2 Guide and Lock Set 1 Should not be loose 3 Float Grommet 2 Should keep float from moving up or down 4 Bell Float 1 5 Float Washer 1 6 Float Rod 1 7 Air Check Brine Well Assembl...

Page 17: ...17 ITEM NO QTY DESCRIPTION 1 1 Fill Plug 2 2 O ring Parts Diagrams Fill Plug Assembly Tank Bottom Figure 18...

Page 18: ...sehold plumbing system Repair the leak No read out in display Electric cord is unplugged Plug in transformer No electric power at outlet Check power source Make sure outlet is not controlled by a swit...

Page 19: ...10 gpm 14 5 Pressure drop service flow rate of 4 gpm 4 0 psi Maximum flow rate to drain during regeneration gpm 2 0 Water Pressure minimum maximum psi 20 120 Controller type 4 Button Regeneration time...

Page 20: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...

Reviews: