STEP 2

Step A –

  Remove nut (Item 11) and blue tubing (Item 12) from 

faucet . (Leave the nut and plastic delrin sleeve (Item 10) on 

the blue tube) .

Step B –

  Feed both the red and black tubing through the pre-drilled 

hole in the sink/counter until faucet is seated .

Step C –

  Under the sink - on to the threaded faucet stem in order 

first slide on the rubber gasket (Item 6), the slotted washer 

(Item 7), the white spacer with the open end UP (Item 8), 

the hex nut washer (Item 9), and lastly secure with nut 

(Item 11) .

Step D –

  Make sure the plastic delrin sleeve (Item 10) is on the end 

of the blue tube; push the white plastic insert (Item 13) into 

the end of blue tubing with the delrin sleeve . Insert the blue 

tube (Item 12) into the faucet stem and secure with nut 

(Item 11) .

Note:  DO NOT overtighten nut.

Standard Faucet Installation

1 . Faucet

2 . Gravity Drainline (

3

8

" Black)

3 . Red Line

4 . Escutchean Plate

5 . Full Circle Rubber Gasket

6 . Slotted Rubber Washer

7 . Slotted Metal Washer

8 . Plastic Spacer or Sleeve

9 . Hex Nut Washer

10 . White Plastic Delrin Sleeve

11 . Water Line Connect or Nut

12 . Blue Water Line

13 . Turn Insert

1

2

3

4

6

4

8
9

10
11

13

12

6

5

7

7

8

9

10

11

13

12

5

Stem

Black

Red

Blue

Sink/Counter

Exploded View

Air Gap Hole 

(See Note) .

Gravity Drain Line 

(See Important)

1. List of Parts and Assembly in Exploded View

2. Complete Assembly

3. Close-up Assembly and Important Notice

Sink Top 

Under Sink

Summary of Contents for PURE WATER PWSYS-RO-STD4-50

Page 1: ...be from Faucet to the Drain Saddle 6 Green Tube Connection 6 Reverse Osmosis Module Mounting 6 Red 1 4 Tube Connection from faucet 6 Check Air Pressure in the Tank 6 Tank Tee Installation 6 Blue Tube...

Page 2: ...d other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended change 2 5 years Stage 3 is the heart of the reverse osmosis system the RO membrane This semi permeable...

Page 3: ...s supplies speciality filters that can be used if copper tubing follows the Reverse Osmosis unit Be sure to follow any state or local regulations during installation Drill a Hole for the Faucet in a P...

Page 4: ...ite plastic insert Item 13 into the end of blue tubing with the delrin sleeve Insert the blue tube Item 12 into the faucet stem and secure with nut Item 11 Note DO NOT overtighten nut Standard Faucet...

Page 5: ...tep B The small square black foam gasket with a circle cut out of the middle must be applied to the inside of the drain saddle Remove sticky tape backing and stick to the drain saddle as shown Step C...

Page 6: ...any RO system tubes at this time STEP 8 Red 1 4 Tube Connection from faucet Step A Using the white plastic union found in the parts bag deter mine where the 1 4 red tubing from the faucet and the 1 4...

Page 7: ...stem contains replaceable treatment components that are critical for effective containment reduction Periodic inspection and following proper system maintenance is critical for continued performance S...

Page 8: ...Line Filter Note Sanitizing of unit is recommended Step A Perform steps A through E in the Six Month System Main tenance Note If not sanitizing the system skip to step H Step B Remove the RO membrane...

Page 9: ...he Adapt A Valve clockwise until it stops Step B Open the RO Faucet and allow water to drain from the tank until it is completely empty Removing the Membrane Step A Use a 5 8 wrench to remove the Gree...

Page 10: ...should be 5 7psi See Page 9 4 Noise Water from faucet vent hole or noise from in drain line drain Crimp or restriction Check tubing and straighten or repair as necessary Straighten all drain lines Cl...

Page 11: ...IRGAP FAUCET CHROME 16 7300030 DRAIN SADDLE 3 8 17 7300022 FLOW RESTRICTOR NOT SHOWN 18 7100331 SEDIMENT FILTER 19 7100446 CARBON BLOCK FILTER 20 7300081 FILTER HOUSING LID 1 4 PORTS 21 7300044 FILTER...

Page 12: ...also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water ut...

Page 13: ...Date of Purchase Date of Install Installed by Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 3rd stage Carbon 6 months Final Filter Carbon 1 year TFM Membrane 2 5 years Notes Service Reco...

Page 14: ...14...

Page 15: ...15...

Page 16: ...ated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLE...