28
SXT Master Programming Mode
When Master Programming Mode is entered, all available option
setting displays may be viewed and set as needed. Depending
on current option settings, some parameters cannot be viewed
or set.
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the pro-
gramming icon replaces the service icon and the parameter
display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button to
resume normal operation. The unit will also return to normal
operation after five seconds if no buttons are pressed.
Entering Master Programming Mode
Set the Time of Day display to 12:01 P. M. Press the Extra Cycle
button (to exit Setting Time of Day mode). Then press and hold
the Up and Down buttons together until the programming icon
replaces the service icon and the display format screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings
and cycle to the next parameter. Press the Extra Cycle button
at the last parameter to save all settings and return to normal
operation. The control will automatically disregard any program-
ming changes and return to normal operation if it is left in Master
Programming mode for 5 minutes without any keypad input.
Resets
Soft Reset
Press and hold the Extra Cycle and Down buttons for 25 sec-
onds while in normal Service mode. This resets all parameters
to the system default values. Not reset are the volume remaining
in meter immediate or meter delayed systems and days since
regeneration in the time clock system.
Master Reset
Hold the Extra Cycle button while powering up the unit. This
resets all of the parameters in the unit. Check and verify the
choices selected in Master Programming Mode.
1. Display Format (Display Code DF)
This is the first screen that appears when entering Master
Programming Mode. The Display Format setting specifies the
unit of measure that will be used for volume and how the control
will display the Time of Day. This option setting is identified by
“DF” in the upper left corner of the screen. There are two
possible settings.
2. Valve Type (Display Code VT)
Press the Extra Cycle button. Use the display to set the
Valve Type.
3. Regenerant Flow (Display Code RF)
Press the Extra Cycle button. The Regenerant Flow Setting
specifies the type of cycle that the valve follows during regenera-
tion. Note that some valve configurations are built with specific
subcomponents. Ensure the valve is configured properly before
changing the Regenerant Flow setting. This option setting is
identified by “RF” in the upper left corner of the screen. There are
eight possible settings.
4. Control Type (Display Code CT)
Press the Extra Cycle button. Use this display to set the Control
Type. This specifies how the control determines when to trigger
a regeneration. For details on how the various options function,
refer to the Control Operation section of this service manual. This
option setting is identified by “CT” in the upper left corner of the
screen. There are four possible settings.
Figure 2
Display Format
Setting
Display Format
Setting
Time Display
GAL
U.S. Gallons
12-Hour AM/PM
Ltr
Liters
24-Hour
Figure 3
Abbreviation
Parameter
dF1b
Standard Downflow Single Backwash
dF2b
Standard Downflow Double Backwash
Fltr
Filter
dFFF
Downflow Fill First
UFbd
Upflow Brine First
UFFF
Upflow Fill First
UFlt
Upflow Filter
O-dF
Other Downflow
O-UF
Other Upflow
Figure 4