2

WARNING

!

Installation Precautions

•   Do 

NOT

 install system on line pressure above 100psi.

•   Do 

NOT

 install system on HOT water line. Failure to limit line 

temperature to 100°F/38°C may result in housing failure and 

damage.

•   Do 

NOT

 install the system backwards with the feed water 

line connected to the outlet.

•   Do 

NOT

 use liquid pipe compounds for fitting connections. 

USE two to three wraps of Teflon® tape.

•   Do 

NOT

 solder plumbing connections attached to filter 

housing or inlet valve. Inlet valve and filter housing will be 

damaged by high temperature.

•   Do 

NOT

 allow system to freeze. Turn off water supply to 

housing and drain housing if temperature falls below 32°F.

•   Do 

NOT

 install system in direct sunlight or where system is 

exposed to harsh chemicals or may be subjected to being 

struck by moving equipment, carts, mops or any other 

item that may cause damage.

• 

 ALLOW

 a minimum of 3" under the housing to allow for 

filter replacement.

•   IF water hammer is evident, install water hammer arrestors 

before the OneFlow

®

 unit. 

•   Do 

NOT

 overtighten fitting connections into inlet valve or 

housing outlet. 

•   Always back-up valves and fittings with a wrench when 

installing a fitting to avoid turning the valve.

•   Do 

NOT

 install the unit behind equipment where it may be dif-

ficult to access the system for filter replacement.

Position the OneFlow

®

 unit in a suitable location. The direction 

of flow through the OneFlow

®

 unit is always left to right; keep 

this in mind when determining installation location. Do NOT 

mount the OneFlow

®

 system near any source of heat. Also, 

do not mount the system above any device or area that would 

be adversely affected by water. 

WARNING

!

•    Connect system to cold water supply only. Water tempera-

ture cannot exceed 100°F/38°C.

•   System 

must be

 installed in a vertical, upright and level position.

•     OneFlow

®

 systems 

must not

 be used in conjunction with 

polyphosphate or any other scale inhibitor.

•    Do not use with water that is microbiologically unsafe or of 

unknown quality without adequate disinfection before or after 

the system.

***Pursuant to the EPA drinking water standards, the copper 

concentration permitted is up to 1.3 ppm. Typically originat-

ing from new copper plumbing, high levels of copper can foul 

OneFlow media. New Copper lines need to be passivated 

for a minumum of 4 weeks before placing unit into service. 

For applications with copper concentration greater than 1.3 

ppm, please consult Watts Water Quality Technical Service. To 

further minimize any problem with excess copper, avoid apply-

ing excessive flux on the inner surfaces of the pipe and use a 

low-corrosivity water soluble flux listed under the ASTM B813 

standard.

NOTICE

† OneFlow

®

 media does not reduce silica scaling. While silica 

tends to have a less significant effect on scale formation than 

other minerals, it can act as a binder that makes water spots and 

scale residue outside the plumbing system difficult to remove. 

This 20 ppm limitation is for aesthetic purposes.
†† All other contaminants must meet the requirements of the 

USEPA Safe Drinking Water Act. Specific Mineral and Metal 

MCL's, identified in Watts published Feed Water Chemistry Re-

quirements, supersedes the USEPA SDWA. 
Water known to have heavy loads of dirt and debris may require 

pre-filtration prior to OneFlow

®

.

pH

6.5-8.5

Hardness (maximum)

30 grains (513 ppm CaCO3)

Water Pressure

15 psi to 90 psi (1.03 bar to 6.21 bar)

Temperature

40° F to 100° F (5°C to 38°C)

Free Chlorine

<2 ppm

Iron (maximum)

0.3 ppm

Manganese (maximum)

0.05 ppm

Copper

1.3 ppm*

Oil & H2S

Must be Removed Prior to OneFlow

Total Phosphates

< 3.0 ppm

Silica (maximum)

20 ppm**

TDS

1500 mg/l****

WARNING

!

Feed Water Chemistry Requirements

NOTICE

* Systems using OneFlow

®

 technology are effective at control-

ling lime-scale formation inside the plumbing system at influent 

hardness levels up to 75 grains per gallon (513 ppm CaCO3) 

of calcium carbonate. Due to variances in water chemistry, 30 

grains per gallon is a recommended hardness maximum due to 

potential aesthetic issues related to soft scale residue formation 

outside of the plumbing system. Testing should be performed to 

determine proper application where hardness levels exceed 30 

grains per gallon.
**Just as with conventional water softening media, OneFlow

®

 

media needs to be protected from excess levels of certain metals 

that can easily coat the active surface, reducing its effectiveness 

over time. Public water supplies rarely, if ever, present a problem, 

but if the water supply is from a private well, confirm that the 

levels of iron (Fe) and manganese (Mn) are less than 0.3 mg/L 

and 0.05 mg/L, respectively.

Summary of Contents for OneFlow OF210-1

Page 1: ...ery 6 months Capacity OF110RM cartridge does not have a grain removal capacity however other contaminants present in the water will gradually degrade the effectiveness of this cartridge Change the OF110RM cartridge at least once a year WARNING Read this Manual BEFORE using this equipment Failure to read and follow all safety and use information can result in death serious personal injury property ...

Page 2: ...high levels of copper can foul OneFlow media New Copper lines need to be passivated for a minumum of 4 weeks before placing unit into service For applications with copper concentration greater than 1 3 ppm please consult Watts Water Quality Technical Service To further minimize any problem with excess copper avoid apply ing excessive flux on the inner surfaces of the pipe and use a low corrosivity...

Page 3: ...he tubing to the equipment at this time Prior to making connection to the equipment this line will be used to facilitate flushing the system As an option a drain valve in a tee on the outlet side of the OneFlow sys tem could be provided in the line to facilitate flushing when changing filters 7 With OneFlow inlet valve closed slowly open the 1 2 full flow ball valve at the tap water source Check f...

Page 4: ...ons 3 3 3 Direction of Flow Operation With sufficient pressure operation of the OneFlow System is completely automatic Dependable operation involves only monitoring of outlet pressure periodic filter changes and service documentation ...

Page 5: ...ve is present disconnect line from equipment to flush to drain NOTICE 10 With water supply inlet valve OPEN and water flow con firmed turn on connected equipment Failure to supply water to equipment may cause serious damage 11 Record filter change on the service log 8 4 7 6 3 2 Maintenance Routine maintenance of your OneFlow System involves periodic filter cartridge changes and or replacement of s...

Page 6: ...ng ID Description 1 Housing 1 2 10 w o PR 1a O Ring 1b Sump only 2 Housing 1 2 10 w o PR 3 Valve 1 2 MXF Ball 4 Nipple 5 Bracket Double Housing White 6 Screw SS 10 x 3 4 7 OF110RC Replacement Cartridge 8 OF110RM Replacement Cartridge 1a 1b 1a 1b ...

Page 7: ......

Page 8: ...e Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow media will be limited to furnishing a replacement for the media within two years from date of original installation Such replacement media will be delivered to the owner F O B nearest factory at no c...

Page 9: ...cartucho OF110RM no tiene capacidad de eliminación de dureza granos sin embargo otros contaminantes presentes en el agua degradarán gradualmente la efectividad de este cartucho Cambie el cartucho OF110RM al menos una vez al año ADVERTENCIA Lea este manual ANTES de utilizar este equipo El no leer y no seguir toda la información de seguridad y de uso puede provocar muerte lesiones personales graves ...

Page 10: ...cobre nuevas deben pasivarse durante un mínimo de 4 semanas antes de poner la unidad en servicio Para aplicaciones con una concentración de cobre mayor a 1 3 ppm comuníquese con el Servicio Técnico de Calidad de Agua de Watts Para minimizar aún más cualquier problema relacionado con el exceso de cobre evite aplicar fundente en exceso en las superficies internas de la tubería y utilice un fundente ...

Page 11: ... NO conecte la tubería al equipo en este momento Antes de conectar al equipo esta línea se utilizará para facilitar el lavado del sistema Como opción se puede proporcionar una válvula de drenaje en una T situada en el lado de salida del sistema OneFlow en la línea para facilitar el lavado al cambiar los filtros 7 Con la válvula de entrada OneFlow cerrada abra lentamente la válvula de bola de flujo...

Page 12: ... 5 FT 0 IN 152 4 cm A F F 3 IN 7 6 CM MÍN ESPACIO LIBRE PARA RETIRAR ESPACIO LIBRE PARA RETIRAR LÍNEA DEL PISO ADAPTADOR MPT DE 1 2 IN 1 27 CM NECESARIO PARA ADAPTARSE A LA ENTRADA DE FPT ADAPTADOR MPT DE 1 2 IN 1 27 CM NECESARIO PARA ADAPTARSE A LA ENTRADA DE FPT ALTURA DE INSTALACIÓN ALTURA DE INSTALACIÓN CONEXIÓN DE SALIDA DE 1 2 IN 1 27 CM FPT AL EQUIPO INSTALE EN UN MURO FIRME SOBRE TRAVESAÑO...

Page 13: ... agua salga limpia Si no hay válvula de lavado desconecte la línea del equipo para que fluya al drenaje AVISO 10 Con la válvula de entrada de suministro de agua ABIERTA y el flujo de agua confirmado encienda el equipo conectado Si no se suministra agua al equipo podrían producirse daños graves 11 Registre el cambio de filtro en el registro de servicio 8 4 7 6 3 2 Mantenimiento El mantenimiento rut...

Page 14: ... 27 cm n º 10 sin PR 1a Junta tórica 1b Solo para sumidero 2 Carcasa 1 2 in 1 27 cm n º 10 sin PR 3 Válvula bola MXF 1 2 in 1 27 cm 4 Boquilla 5 Soporte carcasa doble blanca 6 Tornillo SS n º10 x 3 4 in 1 91 cm 7 Refacción de cartucho OF110RC 8 Refacción de cartucho OF110RM 1a 1b 1a 1b ...

Page 15: ......

Page 16: ...ente Dichos reemplazos se entregarán a la fábrica LAB libre a bordo más cercana al propietario sin costo alguno sin incluir los cargos de flete y mano de obra local si los hubiera Nuestra obligación en virtud de esta garantía con respecto a los medios OneFlow se limitarán a proporcionar un reemplazo de los medios dentro de un plazo de dos años a partir de la fecha de instalación original Dichos me...

Page 17: ...allon ou tous les 6 mois Capacité la cartouche OF110RM ne permet pas d éliminer les grains cependant d autres contaminants présents dans l eau dégraderont graduellement l efficacité de cette cartouche Changer la cartouche de OF110RM au moins une fois par année AVERTISSEMENT Lire ce manuel AVANT d utiliser cet équipement Le non respect de toutes les instructions de sécurité et d utilisation peut en...

Page 18: ... de la plomberie en cuivre peuvent encrasser le média OneFlow Les conduites de cuivre récentes doivent être passivées pendant au moins 4 semaines avant de faire fonctionner l appareil Pour des utilisations où la concentration de cuivre dépasse 1 3 ppm veuillez communiquer avec l équipe d assistance technique de Watts Water Pour réduire davantage tout problème d excès de cuivre évitez d appliquer u...

Page 19: ...uyauterie à l équipement à ce stade Avant de faire le raccordement à l équipement cette conduite sera utilisée pour faciliter la vidange du système Ou un robinet de vidange dans un T sur le côté sortie du système OneFlow pourrait être fourni dans la conduite afin de faciliter la vidange lors du changement des filtres 7 Le clapet d entrée de OneFlow étant fermé ouvrez lentement le clapet à bille pl...

Page 20: ...D ENTRÉE VALVE NON COMPRISE 2 pi 8 po 81 cm MIN 5 pi 152 cm A F F 2 PI 8 PO 81 CM MIN 5 PI 152 CM A F F DÉGAGEMENT POUR LE RETRAIT DÉGAGEMENT POUR LE RETRAIT DÉGAGEMENT POUR LE RETRAIT LIGNE DE PLANCHER Adaptateur MPT po 1 27 cm nécessaire pour s adapter à l entrée FPT ADAPTATEUR MPT PO 1 27 CM NÉCESSAIRE POUR S ADAPTER À L ENTRÉE FPT HAUTEUR D INSTALLATION HAUTEUR D INSTALLATION RACCORD DE SORTIE...

Page 21: ...s de robinet de rinçage détacher la conduite de l équipement pour vidanger dans le drain AVIS 10 Le robinet d entrée de l alimentation d eau étant OUVERT et en présence d un débit d eau mettez l équipement connecté sous tension L équipement pourrait être gravement endommagé s il n y a pas d alimentation d eau 11 Consignez le changement de filtre dans le journal d entretien 8 4 7 6 3 2 Entretien En...

Page 22: ...2 po 1 27 cm nº 10 sans PR 1a Joint torique 1b Puisard seulement 2 Boîtier 1 2 po 1 27 cm nº 10 sans PR 3 Vanne 1 2 po 1 27 cm MXF Ball 4 Mamelon 5 Support double boîtier blanc 6 Vis AI nº 10 x 3 4 7 Cartouche de remplacement OF110RC 8 Cartouche de remplacement OF110RM 1a 1b 1a 1b ...

Page 23: ......

Page 24: ...révèlent défectueuse s pendant la période de garantie indiquée ci dessus Ces pièces de rechange seront livrées au propriétaire F O B franco à bord à l usine la plus proche sans frais à l exclusion des frais de livraison et de main d œuvre locale le cas échéant Notre obligation en vertu de cette garantie par rapport au médium OneFlow sera limitée à fournir un remplacement pour le médium dans les de...

Reviews: