22
SXT Master Programming Mode - Cont’d
19. Relay Setting (Display Code RE)
Press the Extra Cycle button. Use this display to enable the relay
output. This option setting is identified by “RE” in the upper left
corner of the screen. Use the Up and Down buttons to enable
the relay using
either
time based (tb) or flow based (Fb).
Only
one method can be used at a time.
Figure 21
Figure 22
ST Range: 0 to total number of cycles minus 1
Figure 23
ET Range: Start time to total of all cycles
Figure 24
Figure 25
VO Range: 1 to Total Gallon Capacity
Figure 26
TO Range: 1 to 7200 (minutes)
20. End of Master Programming Mode
Press the Extra Cycle button to save all settings and exit Master
Programming Mode.
For time based, set the desired Start Time (ST) and End Time
(ET). Time ranges available are determined by the Regen Cycle
Step Times. For flow based, set the desired Volume Interval (VO)
and Time On (TO).