background image

TROUBLE SHOOTING

Problem   

 Cause    Solution

1. Low/Slow Production  

Low Water Pressure 

 

Assure a minimum of 40 psi incoming water pressure.

 

 

 

 

 

 

 

Premier sells a booster pump if home water pressure is

 

 

 

 

 

 

 

low.  Make sure water supply is turned on and Adapta 

 

 

 

 

 

 

 

Valve is all the way open.

 

 

 

Crimps in tubing 

 

Check tubing and straighten or replace as necessary.

 

 

 

Clogged pre-filters 

 

Replace pre-filters.

 

 

 

Fouled membrane 

 

Replace membrane and flow restrictor.

2. Milky colored Water   

Air in system   

 

Air in the system is a normal occurrence with initial  

 

 

 

 

 

 

 

 

start up of the RO system. This milky look will    

 

 

 

 

 

 

 

 

disappear during normal use within 1-2 weeks.  If  

 

 

 

 

 

 

 

 

condition reoccurs after filter change, drain tank 1 to 2    

 

 

     times.

3. Water constantly  

 

Low water pressure 

 

See #1 Above

    running, unit will not 

    shut off 

 

 

Crimp in supply tube 

 

Check tubing and straighten or repair as necessary.

 

 

 

High water pressure 

 

Check incoming water pressure to make sure it does  

 

 

 

 

 

 

 

 

not exceed 80 psi.  A pressure relief valve may be  

 

 

 

     necessary.

 

 

 

High pressure in Tank   

Empty storage tank of water. Set tank air pressure  

 

 

 

 

 

 

 

 

between 5-7 psi. See previous page.

 

 

 

Low Pressure in Tank   

Use a Digital Air Gauge for best results.  The empty

 

 

 

 

 

 

 

tank pressure should be 5-7 psi. See page 14.

4. Noise / Water from faucet       Crimp or restriction 

 

Check tubing and straighten or repair as necessary. 

    vent hole or noise from 

in drain line 

 

             Straighten all drain lines. Clear blockage.  Cut off any 

    drain. 

 

 

 

 

 

 

Excess tubing

 

 

 

Drain tube clogged 

 

Caused from dishwasher or garbage disposal.

 

 

 

 

 

 

 

Disconnect the 3/8” black line at the drain, clean the  

 

 

 

 

 

 

 

 

3/8” black line out with a wire, then reconnect.  Blowing    

 

 

 

 

 

 

 

air through the line will not always remove the clog.

5. Small amount of water in 

System starting up 

 

Normally it takes 4-6 hours to fill tank.  Note: low  

           

    storage tank 

 

 

 

 

 

 

incoming water pressure and/or temperature can  

 

 

 

     drastically 

reduce 

production 

rate.

 

 

 

Low water pressure 

 

See #1 above.

 

 

 

To much air in tank 

 

Tank air pressure should be 5-7 psi when empty of water.

 

 

 

 

 

 

 

If below 5 psi add air or bleed if above 7 psi.

 

 

 

 

 

 

 

Check only when tank is empty of water.  

 

 

     See 

previous 

page.

6. Water leaks from the blue 

Not properly tightened   

Tighten the bowl.

    or white filter housing  

Kinked O-ring   

 

Turn off the water supply and release the pressure.

 

 

 

 

 

 

 

Replace the O-ring if necessary.  Then lubricate it and

 

 

 

 

 

 

 

make sure the O-ring is seated in the filter bowl    

 

 

 

 

 

 

 

 

properly before reinstalling the filter bowl.

7. Low water flow from faucet  Check air pressure in tank 

Use a Digital Air Gauge for best results.  The empty  

 

 

 

 

 

 

 

 

tank pressure should be 5-7 psi. See page 14.

Summary of Contents for FMRO4G-ERP-75

Page 1: ...Installation Operation and Maintenance Manual FMRO4G ERP 75 Under the counter Reverse Osmosis System...

Page 2: ...ts Thank you for your purchase of a state of the art Reverse Osmosis RO water treatment system Water quality concerns are becoming more of a focus for the public You may have heard about contaminants...

Page 3: ...The second stage contains a 0 5 micron carbon block filter With 20 000 Gallons capacity to ensure that chlorine chloramines and other ma terials that cause bad taste and odor are greatly reduced This...

Page 4: ...ximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Recommended hardness not to exceed 10 grains per gallon or 170ppm System will operate with hardness over 10 grains but the me...

Page 5: ...s on the faucet installation are for reference only Drill a pilot hole use the Hole Punch and an adjustable wrench to punch the hole in the sink Step 5 If mounting faucet to a Stainless Steel Sink you...

Page 6: ...tion the tube can be removed The fitting can then be reused Feed Water Valve Installation Continued Turn off the cold water supply to the faucet by turning the angle stop valve completely off Attach t...

Page 7: ...3 8 barb on the faucet If your air gap faucet has no tubes attached Typical RO Faucet Installation 3 8 BLUE TUBING FROM RO MODULE 1 4 RED LINE TO RO MODULE 3 8 BLUE TUBING FROM RO MODULE Drinking Fee...

Page 8: ...low for proper drainage This is a gravity fed line and if there is any bend or dip in the tube the rinse water will not flow into the drain properly Water may back up and come out the air gap hole in...

Page 9: ...bit screw them into the cabinet wall 6 apart and 16 from the bottom of the cabinet Yellow Tube Connection RO Module to Storage Tank Step 19 Position the storage tank in desired location Measure the ye...

Page 10: ...ing process should take about a day to complete Open the RO faucet and leave it open until water begins to trickle out it will come out slowly Step 4 Turn on the incoming cold water at the angle stop...

Page 11: ...er Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Insert a new sedime...

Page 12: ...l the storage tank is completely drained Open the membrane housing and re install the RO membrane while making sure not to kink the O rings Refer to Membrane Re placement section on page 13 for direct...

Page 13: ...m Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 2 Removing the membrane Installing the membrane Remove the end cap from the membrane housing by turning it...

Page 14: ...side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet still in the open po sition you may add air to the tank to purge any left over water t...

Page 15: ...tank pressure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tubing and straighten or repair as necessary vent hole or noise from in drain line Straighten all drain...

Page 16: ...e BW60 1812 75 Post Filter AICRO Faucet FU WDF 103NSF Metal Tank FRO 132 WH Plastic Tank ROPRO4 W Feed water valve F560080 Components This system doesn t come with a faucet The below notes on the fauc...

Page 17: ...ecord Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2 nd stage Carbon 6 months Final Filter Carbon 1 year TFC Mebrane 2...

Page 18: ...ecord Date of Purchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2 nd stage Carbon 6 months Final Filter Carbon 1 year TFC Mebrane 2...

Page 19: ......

Page 20: ...rees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the sy...

Reviews: