16
7
Troubleshooting & Solution
My
BT DRF-02
doesn’t start
Batteries
Problem
- Check if the protection sticker on the
batteries is removed.
- Check the batteries orientation.
- Check the capacity of the batteries
My
BT DRF-02
Led, blinks in Red
Problem on
sensors
The logo blinks (ambient sensor)
- Contact your installer or seller.
The logo blinks (Floor sensor)
- Check the connection of the sensor.
- Disconnect the sensor, and check it
with an ohmmeter (the value must be
around 10kohms)
Batteries level is
too less
The logo blinks (Batteries)
- Replace the batteries.
My
BT DRF-02
seems work correctly but the heating doesn’t
work correctly
Output
On the receiver:
- check the good reception of RF signal
- Check the connections.
- Check the power supply of the heating
element.
- Contact your installer.
RF
communication
- Check the following points :
- The receiver must be put at a
minimum distance of 50cm of all
others electrical or wireless materials
(GSM, Wi-Fi..)
-
The receiver shouldn’t be fixed on a
metallic part or too close of hydraulic
pipes… (Copper…)
Summary of Contents for BT-DRF-02
Page 1: ...1 BT DRF 02 ...
Page 23: ...23 ...
Page 45: ...45 ...
Page 81: ...81 8 Pokročilé instalační menu parametrů Entrada en el menú del termóstato BT DRF 02 5s ...
Page 86: ...86 PPLIMF15053Ba ...