VT+ 

Installation and Operation Manual 

UK 

 

Indice de protection 

 

IP68 

Enclosure protection 

600Nm 

 

Facteur de marche 

 

50% 

Duty cycle 

Anticondensation 

intégrée 

 
 
 
 

Anticondensation 

Heater 

Positionnement 

 

POSI 

Positioning 

 

 

BLUETOOTH

®

 

 

Electric actuator 

Summary of Contents for ARA VT+

Page 1: ...and Operation Manual UK Indice de protection IP68 Enclosure protection 600Nm Facteur de marche 50 Duty cycle Anticondensation intégrée Anticondensation Heater Positionnement POSI Positioning BLUETOOTH Electric actuator ...

Page 2: ...rnings Multipin connector Electronic boards Operating modes Wiring modulating 3 point On off Pulse control Positioning function AXMART Bluetooth function Technical data 14 Codification 16 This product meets the European Directive 2012 19 UE about electrical and electronic equipment DEEE It mustn t be mixed with common waste Please recycle or dispose of them according to your country laws ...

Page 3: ...cluded from the guarantee In the case where a custom er has not proceeded to payments within the agreed period our guarantee will be suspended until the delayed pay ments have been received and with the consequence that this suspension will not prolong the guarantee period in any case All sales subject to our terms to be found on our website RETURN OF GOODS When the actuator receives his actuator ...

Page 4: ...ENGLISH DSBA3600 Rév 18 07 2019 UK Dimensions 600 and 1000Nm models Star mm Depth mm 36 41 ISO 5211 connection Diameter mm F10 102 F12 125 M threated Depth mm M10 25 M12 30 Screw number 4 4 ...

Page 5: ...LISH DSBA3600 Rév 18 07 2019 UK Dimensions 1500 and 2400Nm models Star mm Depth mm 46 50 ISO 5211 connection Diameter mm F12 125 F14 140 M threated Depth mm M12 20 M16 25 Screw number 4 4 F16 165 M20 30 4 ...

Page 6: ...f its nominal sys tem operating voltage It is necessary to connect all actuators to an electrical cabinet The power supply cables must have the RATED diameter for the maximum current supported by the actuator and comply with IEC 60227 or IEC 60245 standards The selection of the cables and cable glands the maximal operating temperature of the cables and cable glands must be at least 110 C In order ...

Page 7: ...20 x 1 5 cable glands 6 Connector cover To wire the actuator unscrew the 4 CHC M6x30 screws and the 4 M3x10 screws The wiring can be realized without tool just raising the strips in front of each pin For the reassembly make sure that the seal is cor rectly positioned in its groove to ensure tightness 1 2 3 4 5 6 Multipin connector ...

Page 8: ...PPLY 100V to 240V AC 50 60Hz and 100V to 300V DC 24V to 48V AC 50 60Hz and 24V to 72V DC TP PE 6 5 4 3 2 1 1 Power supply terminal 4 Feedback signal positioning mode 2 Failure report 24V 3A max 5 Learning mode panel positioning mode 3 Setpoint signal positioning mode 6 Functioning mode selection panel FUSES SNBA050000 3 x T 5A 250V Littlefuse SNBA051000 3 x 20A 72V DC Shurter TP PE Protection eart...

Page 9: ... the AXMART software Weekly scheduler Bluetooth thanks to AXMART you can assign up to 20 repeatable tasks to each actuator This mode requires a smartphone or a tablet with the AXMART software Wire control electric control permanent on off or 3 modulating point or pulse Positioning learning mode this mode is needed for storing limit positions of the actuator Positioning allows the control of the ac...

Page 10: ...tween two impulssions 1 2 3 13 14 15 16 17 18 TP PE Open Close Neutral Phase AC 50 60Hz DC 1 2 3 13 14 15 16 17 18 TP PE Neutral Phase AC 50 60Hz DC Open Neutral Phase AC 50 60Hz DC 13 14 15 16 17 18 TP PE 1 2 3 4 A feedback signal 4 20mA or 0 10V is avai lable from terminal 9 10 11 whichever your selected control mode is See wiring diagram page 23 ...

Page 11: ...ressed during 2 seconds The APPR1 led blinks and lights up The closed position is correctly recorded Press APPR Open button to drive the valve up to its open position and keep both APPR Open and APPR Mem buttons pressed during 2 seconds The APPR2 led blinks and lights up The open position is correctly recorded Both open and closed positions are recorded Select positioning POSI mode and press OK Mo...

Page 12: ... UK Positioning function wiring TP PE 13 14 15 16 17 18 1 2 Neutral Phase AC 50 60Hz DC Setpoint signal Setpoint signal feedback feedback feedback 9 10 11 24 12 The 0 10V and 4 20mA feedback signals are not available at the same time ...

Page 13: ...l with maximum range of 20m in open field Weekly scheduling Thanks to AXMART software the actuator can be programmed to schedule up to 20 tasks weekly repeatable The actuator will become a stand alone unit For any further information refer to the operation manual reference DSBA3303 Bluetooth function ...

Page 14: ...ded environment is 2 in most cases Weight 25kg Mechanical data Maximum torque 600Nm 1000Nm Operating time 90 42s 65s Angular range 90 180 270 on request Duty cycle 50 Drive ISO5211 Star 36 F10 F12 Manual control Secured handwheel without clutching system Electrical data Electric connection 3 x ISO M20 and specific multipin connector Technology of motors Brushless Voltages1 100V to 240V AC 50 60Hz a...

Page 15: ...cable POLLUTION DEGREE of the intended environment is 2 in most cases Weight 57kg Mechanical data Maximum torque 1500Nm 2400Nm Operating time 90 155s 210s Angular range 90 180 270 on request Duty cycle 50 Drive ISO5211 Star 46 F12 F14 F16 Manual control Secured handwheel without clutching system Electrical data Electric connection 3 x ISO M20 and specific multipin connector Technology of motors Bru...

Page 16: ... F10 F12 B Star 46 F14 C Star 46 F12 F16 D Special E Keyway bore Ø40 F12 F16 0 Standard 3 Long operating time A 100V to 240V 50Hz 60Hz and 100V to 300V DC B 24V to 48V 50Hz 60HZ and 24V to 72V DC G 50 00 3 modulating points ON OFF mode 11 4 wire control P7 Positioning T Counter clockwise closing L Application with vibrations M Marine coating Codification ...