background image

IS-FloodSensor-957/994/Colt/SS-BMS   2250 

0834331 

© 2022 Watts

Limited Warranty:

 Watts (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for 

a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, 
replace or recondition the product without charge. 

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE 
PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL 
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the 
Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of 
repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, 
vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over 
which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper 
maintenance or alteration of the product. 
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of inci-
dental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, 
and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. 

SO FAR AS 

IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE 
DATE OF ORIGINAL SHIPMENT.

USA:

  T: (978) 689-6066 • Watts.com

Canada:  

T: (888) 208-8927 • Watts.ca

Latin America:  

T: (52) 55-4122-0138 • Watts.com

Attach the Sensor Activation Module Cable to the BMS Controller

The 4-conductor sensor activation module cable should be attached to the BMS controller to transmit a 
normally open contact signal and provide power to the sensor activation module. The contact signal 
closes when a discharge is detected.

To connect the module cable to  

the controller

1.   Use the wire stripper to cut away enough insulation to 

expose 1 to 2 inches of the conductor wires.

2.   Insert the white and green wires into the input terminal.

Either the BMS power source (ranging from 12V to 24V) 
or the 24V DC power adapter provided can be used. With 
each power source, an earth ground connection is required. 

If using the optional power adapter, skip to the next set of 
instructions. Be sure to use the ground wire provided if there 
is no other earth ground on the BMS controller.

NOTICE

To use the optional 24V DC power adapter

Distinguish the positive wire from the negative one. The 
positive wire has white stripes and must be inserted into the 
power terminal; the negative wire, into the ground terminal.

1.   Connect the positive power adapter wire (black with white 

stripe) to the red wire of the sensor activation module 
cable and insert the wires into the power terminal.

2.   Connect the negative power adapter wire (black with 

no stripe) to both the black wire of the sensor activation 
module cable and the ground wire (if needed) then insert 
the wires into the ground terminal.

3.   Plug the power adapter into a 120VAC, 60Hz, GFI-

protected electrical outlet.

The flood sensor LED is steady green when the unit is ready.

The earth ground must be connected to the BMS controller 
before the flood sensor is put in operation.

WARNING

!

3.   Insert the red wire in the power terminal. (A power source 

ranging from 12V to 24V is required.)

4.   Insert the black wire in the ground terminal.

Summary of Contents for 957-FS Series

Page 1: ... valve discharge with smart and connected technology to detect and notify of flooding The BMS Sensor Connection Kit activates the integrated flood sensor to enable functions that detect flood conditions The BMS Sensor Retrofit Connection Kit upgrades existing installations by integrating and activating the flood sensor to enable functions for flood detection When excessive relief valve discharge o...

Page 2: ...AC 60Hz GFI protected electrical outlet for kit power adapter or power source ranging from 12V to 24V Wire stripper A Sensor activation module with an 8 4 conductor electrical cable ground wire and 4 attachment screws B 24V DC power adapter The connection kits are suitable for installation on the specified valve series only NOTICE C Flood sensor with mounting bolts retrofit kit only When installin...

Page 3: ...ings The default settings on the sensor activation module for detecting discharge are suitable for the assembly series However the DIP switches can customized for a different wet threshold and time delay Scan the QR code for more information 1 Remove the bolts from the flood sensor 2 Position the two halves of the sensor on the relief valve 3 Insert the bolts and tighten 4 Remove the dust cover fr...

Page 4: ...STATE LAW ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT USA T 978 689 6066 Watts com Canada T 888 208 8927 Watts ca Latin America T 52 55 4122 0138 Watts com Attach the Sensor Activation Module Cable to the BMS Controller The 4 conducto...

Page 5: ...ogie intelligente et connectée pour détecter et signaler les inondations La trousse de connexion de capteur de BMS active le capteur d inondation intégré pour assurer les fonctions de détection des conditions d inondation La trousse de connexion de modernisation de capteur de BMS met à niveau les installations existantes en intégrant et en activant le capteur d inondation pour activer les fonction...

Page 6: ... terre de 120 V CA 60 Hz pour l adaptateur d alimentation de la trousse ou source d alimentation allant de 12 V à 24 V Pince à dénuder A Module d activation du capteur avec câble électrique à 4 conducteurs de 8 pi 2 4 m et fil de mise à la terre et 4 vis de fixation B Adaptateur d alimentation 24 V CC Les trousses de connexion conviennent uniquement à une installation sur la série de vannes spécif...

Page 7: ...r défaut sur le module d activation du capteur pour la détection de décharge conviennent à la série de l assemblage Cependant les commutateurs DIP peuvent être personnalisés pour régler un seuil d humidité et une temporisation différents Balayez le code QR pour plus d informations 1 Retirez les boulons du capteur d inondation 2 Positionnez les deux moitiés du capteur sur la soupape de décharge 3 P...

Page 8: ...URÉE DE TOUTE GARANTIE IMPLICITE PRÉVUE PAR LA LOI EN APPLICATION ET DEVANT DONC ÊTRE ASSUMÉE Y COMPRIS LES GARANTIES IMPLICITES DE QUALITÉ MARCHANDE ET D APTITUDE À UN USAGE PARTICULIER SERA LIMITÉE À UN AN À PARTIR DE LA DATE DE L EXPÉDITION D ORIGINE É U Tél 978 689 6066 Watts com Canada Tél 888 208 8927 Watts ca Amérique latine Tél 52 55 4122 0138 Watts com Fixez le câble du module d activatio...

Page 9: ...s y notificar sobre inundación El kit de conexión del sensor del BMS activa el sensor de inundación integrado para habilitar funciones que detectan condiciones de inundación El kit de conexión de retroadaptación del sensor del BMS actualiza las instalaciones existentes mediante la integración y activación del sensor de inundación para permitir funciones para la detección de inundaciones Cuando ocu...

Page 10: ...protección GFI para el adaptador de alimentación del kit o fuente de alimentación de 12 V a 24 V Pelacables A Módulo de activación del sensor con un cable eléctrico de 8 ft 2 4 m con cable eléctrico de 4 conductores cable de tierra y 4 tornillos de fijación B Adaptador de alimentación de 24 V Los kits de conexión son adecuados para la instalación en la serie de válvulas especificada únicamente AVI...

Page 11: ...ón Los ajustes predeterminados del módulo de activación del sensor para detectar descargas son adecuados para la serie de montaje Sin embargo los interruptores DIP pueden personalizarse para un umbral húmedo y retardo de tiempo diferentes Escanee el código QR para obtener más información 1 Retire los pernos del sensor de inundación 2 Coloque las dos mitades del sensor en la válvula de alivio 3 Ins...

Page 12: ...DA NO SER RENUNCIADA INCLUYENDO LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN PROPÓSITO PARTICULAR TIENEN UNA DURACIÓN LIMITADA A UN AÑO A PARTIR DE LA FECHA DE ENVÍO ORIGINAL EE UU T 978 689 6066 Watts com Canadá T 888 208 8927 Watts ca América Latina T 52 55 4122 0138 Watts com Conecte el cable del módulo de activación del sensor al controlador del BMS El cable del módulo de ac...

Reviews: