Watts 4000SS-FS Series Instruction, Installation, Maintenance And Repair Manual Download Page 7

7

Add-on and Retrofit Sensor Connection Kits for Building Management Systems

ORDERING CODE

ADD-ON/RETROFIT KIT

DESCRIPTION

88009418

FP-BF-BMS-21/2-10

BMS Sensor Connection Kit

Series 4000SS-FS

Series 5000SS-FS

Sizes 2½" to 6"

Includes sensor activation module with cable, ground wire, and power adapter. Use 

this kit to activate the integrated flood sensor and enable flood detection capabilities 

on the relief valve of a new installation linked to a BMS controller (not included).

88009419

FP-RFK-BF-BMS-CFS-21/2-10

BMS Sensor Retrofit Connection Kit

Series 4000SS

Series 5000SS

Sizes 2½" to 6"

Includes flood sensor, sensor activation module with cable, ground wire, and 

power adapter. Use this kit to install the flood sensor and enable flood detection 

capabilities on the relief valve of an existing installation linked to a BMS controller 

(not included).

Add-on and Retrofit Sensor Connection Kits for Cellular Communication

ORDERING CODE

ADD-ON/RETROFIT KIT

DESCRIPTION

88009420

FP-BF-CFS-21/2-10

Cellular Sensor Connection Kit

Series 4000SS-FS

Series 5000SS-FS

Sizes 2½" to 6"

Includes sensor activation module with cable, Cellular Gateway with mounting kit, 

ground wire, and power adapter. Use this kit to activate the integrated flood sensor 

and enable flood detection capabilities on the relief valve of a new installation linked 

to a cellular network to send alerts by email message, SMS text message, or 

voice call.

88009421

FP-RFK-BF-CFS-21/2-10

Cellular Sensor Retrofit Connection Kit

Series 4000SS

Series 5000SS

Sizes 2½" to 6"

Includes flood sensor, sensor activation module with cable, Cellular Gateway with 

mounting kit, ground wire, and power adapter. Use this kit to install the flood sensor 

and enable flood detection capabilities on the relief valve of an existing installation 

linked to a cellular network to send alerts by email message, SMS text message, 

or voice call.

Summary of Contents for 4000SS-FS Series

Page 1: ...the service intended Regular checking and cleaning of the product s internal components helps assure maximum life and proper product function WARNING WARNING The installation and maintenance of backfl...

Page 2: ...ater authorities must approve all installation configurations Allow sufficient clearance around the installed assembly to conduct testing servicing and inspection Allow a minimum of 12 from the flood...

Page 3: ...lapper so that the end of the check arm rests between the roller and the clapper See Figure 5B Thoroughly clean the seat area and clapper sealing surfaces of both checks Inspect seats clapper sealing...

Page 4: ...hragm with the cupped hand The trapped air in the dia phragm forces the diaphragm between the inside of the sleeve and the outside of the piston Ensure that the diaphragm is fully seated If diaphragm...

Page 5: ...nect vent hose at test cock No 4 Open valves B and C bleeding to atmosphere Then closing valve B restores the system to a normal static condition Observe the pressure differential gauge If there is a...

Page 6: ...ure Leak through diaphragm or around flange bolt holes of relief valve Service relief valve Pressure relief valve does not close See problem Pressure relief valve does not close Assembly discharges fr...

Page 7: ...not included Add on and Retrofit Sensor Connection Kits for Cellular Communication ORDERING CODE ADD ON RETROFIT KIT DESCRIPTION 88009420 FP BF CFS 21 2 10 Cellular Sensor Connection Kit Series 4000S...

Page 8: ...s resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Company has no con...

Reviews: