background image

Page 16

  
 
 
 
  

 

 

 

 
 
 

 
 

 

TROUBLE SHOOTING

Problem   

 Cause    Solution

1. Low/Slow Production  

Low Water Pressure 

 

Assure a minimum of 40 psi incoming water pressure.

 

 

 

 

 

 

 

Premier sells a booster pump if home water pressure is

 

 

 

 

 

 

 

low.  Maker sure water supply is turned on and Adapta 

 

 

 

 

 

 

 

Valve is all the way open

 

 

 

Crimps in tubing 

 

Check tubing and straighten or replace as necessary.

 

 

 

Clogged pre-filters 

 

Replace pre-filters.

 

 

 

Fouled membrane 

 

Replace membrane and clean flow restrictor.

2. Milky colored Water   

Air in system 

 

 

Air in the system is a normal occurrence with initial start 

 

 

 

 

 

 

 

up of the RO system.  This milky look will disappear 

 

 

 

 

 

 

 

during normal use within 1-2 weeks.  If condition reoccurs

 

 

 

 

 

 

 

after filter change, drain tank 1 to 2 times.

3. Water constantly  

 

Low water pressure 

 

See #1 Above

running unit will not
shut off 

 

 

Fouled membrane 

 

Replace membrane

 

 

 

High water pressure 

 

Check incoming water pressure to make sure it does not

 

 

 

 

 

 

 

exceed 100 psi.  A presser relief valve may be necessary.

 

 

 

High air pressure in tank 

Empty storage tank of water. Set tank air pressure to 5

 

 

     psi. 

See 

previous 

page.

4. Noise from faucet or drain 

Air gap faucet   

 

Inherent sound with air-gap faucets.

 

 

 

Location of drain saddle  

See diagram for proper location of drain saddle. 

 

 

 

Higher capacity membrane 

Normal with high capacity membrane

 

 

 

High water pressure 

 

Check incoming water pressure to make sure it does not

 

 

 

 

 

 

 

exceed 100 psi.  A presser relief valve may be necessary. 

 

5. Faucet leaks from 

 

Crimp or loop in drain line 

Straighten black 3/8 drain tube.  Cut off any excess tubing

the air gap feature   

 

Drain tube clogged/restricted 

Caused from dishwasher or garbage disposal.

 

 

 

 

 

 

 

Disconnect the 3/8” black tube at the drain, clean the 3/8”

 

 

 

 

 

 

 

black tube out with a wire, then reconnect.  

6. Small amount of water in  

System just starting up   

Normally it takes 6-10 hours to fill tank.  Note: Low

storage tank 

 

 

 

 

 

 

pressure and/or temperature can drastically reduce

 

 

     production 

rate.

 

 

 

Low water pressure 

 

See #1 Above

 

 

 

Too much air in tank 

 

Add air if below 5 psi and bleed if above 5 psi. Check 

 

 

 

 

 

 

 

only when tank is empty of water.  See previous page.

   

 

7. Water leaks from the   

Not properly tightened.   

Tighten the bowl

filter housing 

 

 

Missing or kinked O-ring  

Turn off the water supply.  Release the pressure, remove 

 

 

 

 

 

 

 

bowl and replace the O-ring.  (p/n 113043). Make sure    

 

 

 

 

 

 

 

the O-ring is seated in the filter bowl properly before 

 

 

 

 

 

 

 

reinstalling the filter bowl.

 

 

 

     

Summary of Contents for WP-4

Page 1: ...3 866 5666 Save manual for future reference MODEL WP 4 WP4 50 KP 4 RO 4M Warning Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating...

Page 2: ...iment and other particulate matter like dirt silt and rust which affect the taste and appearance of your water Stage 2 Carbon filter recommended change 6 months The second stage contains a 5 micron ca...

Page 3: ...teel Sink 5 Faucet Installation 6 Adapt a Valve Installation 7 Drain Saddle Installation 7 Drill hole and Connect 3 8 Black Tube from Faucet to the Drain Saddle 8 Green Tube Connection 8 Reverse Osmos...

Page 4: ...r line only Copper Tubing Reverse Osmosis water should not be run through copper tubing as the purity of the water will leach copper causing an objectional taste in water and pin holes may form in the...

Page 5: ...cating oil or liquid soap to keep the hole saw cool during cutting Step 2 Drill a Hole for the Faucet in a Porcelain Sink Punch a Hole for the Faucet in a Stainless Steel Sink Drill a pilot hole Use a...

Page 6: ...r first slide on the rubber gasket item 6 the slotted washer item 7 the white spacer with the open end UP item 8 the hex nut washer item 9 and lastly secure with nut item 11 Step 8 Make sure the plast...

Page 7: ...as shown 1 Black compression nut 1 Semicircle bracket with opening 2 Screws 1 Foam gasket 2 Nuts for screws 1 Semicircle bracket Gather the pieces of the drain saddle Caution Do not over tighten the...

Page 8: ...sing an electric drill with a Phillips bit screw them into the cabinet wall 6 apart and 16 from the bottom of the cabinet Do not cut any RO system tubes at this time Note With the drain saddle secured...

Page 9: ...Guest locking system holds the tube firmly in place without deforming it or restricting flow It is essential that the outside diameter be free of score marks and that burrs and sharp edges be removed...

Page 10: ...t fitting on the RO Manifold Make sure the tube is pushed in all the way to the tube stop See Picture Insert the blue 3 8 tube from the faucet into the port on the module marked FAUCET Make sure the t...

Page 11: ...that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drinking Don t Forget To Register Open the RO faucet a...

Page 12: ...th System Maintenance Turn off the incoming water supply to the RO at the adapt a valve Follow the green tube away from the RO system to find the adapt a valve Step 1 Step 3 Step 4 Step 5 Step 6 Let s...

Page 13: ...er run for 30 seconds Turn off the RO faucet and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Turn off the incoming water supply to the system by...

Page 14: ...such as KY Jelly Insert the end with the two black O rings into the cap Twist the membrane as you push it firmly into the manifold Step 4 Step 5 Step 6 Replace the membrane housing onto the cap by tur...

Page 15: ...k Air Pressure in the Tank Important Step 3 Check air pressure only when tank is empty of water Step 1 Turn off the incoming water supply to the RO at the adapt a valve Follow the green tube away from...

Page 16: ...et or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with high capacity membrane High...

Page 17: ...to pentavalent arsenic A combined chlorine residual also called chloramine may not convert all the trivalent arsenic If you get your water from a public water utility contact the utility to find out...

Page 18: ...ead Radium 226 228 Selenium Perchlorate 100 ug L 2 None Microbiological Contaminants and Turbidity Inorganic Radiological Contaminants Organic Contaminants not applicable Rated Service Capacity 9 gall...

Page 19: ...50 psi 0 005 mg L 0 10 10 0 006 Radium 226 228 25pCi L 5pCi L 80 0 7 24 50psi 5pCi L 25pCiL 10 5pCiL Selenium 0 10 0 001 99 0 50psi 0 001 0 10 10 0 05 TDS 765 24 96 8 7 84 50psi 39 0 750 40mg L 187 T...

Page 20: ...duction Rate 9 86 GPD Efficiency 6 08 Depending on water chemistry water temperature and water pressure Watts Premier s R O Systems production and performance will vary Efficiency rating means the per...

Page 21: ...brane 50GPD 5 3 113018 Filter Bowl 6 1 113035 Membrane Vessel 7 3 113041 O Ring Filter Bowl 8 1 113045 O Ring Membrane Vessel 9 1 116001 Faucet AG Chrome 10 1 119007 Tank Pressure 3GAL White 11 1 1250...

Page 22: ...unique top mount design allows for easy above counter installation The Monitored version of this faucet has an LED light that turns red to notify you for filter replacement Part No 116091 Chrome Non...

Page 23: ...ws the membrane to maximize its use of the available feed pressure PERMEATE PUMP KIT Part No 560041 65 95 ea Fills product tank up to 4 times more rapidly Reduces waste water by as much as 80 Lowers T...

Page 24: ...xtension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Ma...

Page 25: ...ter your information XXXXX XXXXXX Watts Premier Inc is concerned for the safety of your personal information Watts Premier collects personal information when you register with Watts Premier This infor...

Page 26: ...ntry USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed...

Page 27: ...of Purchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st Stage Sediment 6 months 2nd Stage Carbon 6 months 4th Stage Carbon 1 year T...

Page 28: ...re inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is microbiologically unsafe or of...

Reviews: