Watts Premier FILTER-PURE Installation, Operation And Maintenance Manual Download Page 10

Performance Data Sheet

Watts Premier Inc. 

8716 W Ludlow Drive Suite #1

Peoria, AZ 85381

 

 

 

 

 

      

FILTER PURE

GENERAL USE CONDITIONS:

1: System has been independently tested for the removal of microbiologically contaminated water.  The system is not intended 
for the treatment of water that has an obvious contamination source, such as raw sewage. This system is not intended to 
convert wastewater to microbiologically safe drinking water.

2: Operating Temperature: 

 

Maximum  100

F (37.8

C) 

 

Minimum 40

F (4.4

C)

3: Operating Water Pressure:  

Maximum  85-psi (5.98 kg/cm

2

)   

Minimum 20-psi 

4: Maximum flow Rate:   

0.50 gpm (1.89 lpm)

5: Rated Capacity: 

 

2000 Gallons (7,500 liters)

RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:

Note: Depending on incoming feed water conditions replacement time frame may vary.
Description 

   Part 

Number 

 Change 

Time 

Frame 

Cost

Stage 1: Sediment:  

 

 

105311   

 

6 Months 

 

$  9.95*

Stage 

2: 

Carbonblock 

 

  105351 

  6 

Months  $15.95*

*All prices subject to change without notice

This system has been tested according to NSF/ANSI Standard 42 for the reduction of the substances listed below.  The concentration of the indicated 
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as 

specified in NSF/ANSI 42. Testing performed under standard laboratory conditions, actual performance may vary.

California Proposition 65 Warning
WARNING: this product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. (Installer: 
California law requires that this warning be given to the consumer). For more information: www.wattsind.com/prop65.

Contaminant 

 

 

Influent Challenge Concentration 

 

Percent Reduction Achieved

Chlorine Taste & Odor 

 

 

2.0 mg/L + 10% 

 

 

 

97%

Particles   

 

 

 

Class IV   

 

 

 

96%

Questions? Contact Watts Premier 

800-752-5582 

        www.wattspremier.com

      480-675-7995
      

10

Summary of Contents for FILTER-PURE

Page 1: ...5582 www wattspremier com Fax 623 866 5666 Part 199408 Manual Date 10 26 2011 Please read carefully before proceeding with installation Your failure to follow any attached instructions or operating p...

Page 2: ...n including cysts like Cryptosporidium Toxoplasma Giardia and Entamoeba Lead and VOC filter block for the reduction of lead and harmful chemicals It is estimated that VOC s are present in one fifth of...

Page 3: ...g Blue tube to faucet Adapt a Valve Installation System Start Up Filter Change Performance Data Sheet Other Products by Watts Warranty Registration Service Record Warranty 4 4 4 5 5 5 6 7 7 8 8 9 10 1...

Page 4: ...plumbing regulations Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system System is intended to be installed using the...

Page 5: ...2 self tapping screws Using an electric drill with a Phillips bit screw them into the cabinet wall Mount the filtration system Step 5 5 Flow Diagram Step 1 The two quick connect elbows are pre instal...

Page 6: ...the Faucet in a Stainless Steel Sink Drill a 1 8 pilot hole Use a 1 2 Hole Punch and an adjustable wrench to punch the hole in the sink Step 10 The faucet can now be installed If mounting faucet to a...

Page 7: ...the open end of the blue tube attached to the filtration system then the plastic ferrule sleeve small tapered end of sleeve pointing to the end of tube finally push the white plastic insert all the w...

Page 8: ...filtration system Insert the open end of the green 1 4 tube into the open 1 4 quick connect fitting on the plastic adapt a valve making sure the tube is pushed in all the way passed the o ring to the...

Page 9: ...swiveled up to 90 degrees as shown in the pictures below Step 2 To install a filter cartridge Remove the seal cap and insert the cartridge into the valved head until you hear an audible click the but...

Page 10: ...1 Sediment 105311 6 Months 9 95 Stage 2 Carbonblock 105351 6 Months 15 95 All prices subject to change without notice This system has been tested according to NSF ANSI Standard 42 for the reduction o...

Page 11: ...nology and high production 24gpd Thin Film Membrane NSF Certified for the reduction of a wide range of contaminants including Arsenic Chromium Perchlorate Lead Radium and many others Part No 500023 23...

Page 12: ...Swivel Ball Extension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter De...

Page 13: ...stration information for you XXXXX XXXXXX Watts Premier Inc is concerned for the safety of your personal information Watts Premier collects personal information when you register with Watts Premier Th...

Page 14: ...ry USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed B...

Page 15: ...se __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Date Carbon Block 6 Months Carbon Block 6 Months Sediment Filter 6 months Model Number ________...

Page 16: ...ter Top cannot exceed 100 degrees F 38 degrees C This warranty does not cover any equipment that is relocated from the site of its original installation This warranty doe not cover any charges incurre...

Reviews: