Performance Data Sheet
Watts Premier Inc.
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
FILTER PURE
GENERAL USE CONDITIONS:
1: System has been independently tested for the removal of microbiologically contaminated water. The system is not intended
for the treatment of water that has an obvious contamination source, such as raw sewage. This system is not intended to
convert wastewater to microbiologically safe drinking water.
2: Operating Temperature:
Maximum 100
o
F (37.8
o
C)
Minimum 40
o
F (4.4
o
C)
3: Operating Water Pressure:
Maximum 85-psi (5.98 kg/cm
2
)
Minimum 20-psi
4: Maximum flow Rate:
0.50 gpm (1.89 lpm)
5: Rated Capacity:
2000 Gallons (7,500 liters)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Part
Number
Change
Time
Frame
Cost
Stage 1: Sediment:
105311
6 Months
$ 9.95*
Stage
2:
Carbonblock
105351
6
Months $15.95*
*All prices subject to change without notice
This system has been tested according to NSF/ANSI Standard 42 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42. Testing performed under standard laboratory conditions, actual performance may vary.
California Proposition 65 Warning
WARNING: this product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. (Installer:
California law requires that this warning be given to the consumer). For more information: www.wattsind.com/prop65.
Contaminant
Influent Challenge Concentration
Percent Reduction Achieved
Chlorine Taste & Odor
2.0 mg/L + 10%
97%
Particles
Class IV
96%
Questions? Contact Watts Premier
800-752-5582
www.wattspremier.com
480-675-7995