4 Mode of Energy Monitor

3  ENERGY HISTORY Mode

Fig. 20

From the COST Mode, press the [ 

Set button

1

2 TIMES

 to switch to the 

ENERGY  HISTORY  Mode  (as  Fig.  19),  which  displays  the  history  data  of 
total electricity energy consumption of all channels.

Fig. 19

Press 2 TIMES

In  Fig.  23,  there  are  three  kinds  of  energy  history  data  automatically 
switching among each other in every 5 seconds.

TODAY 

MTD 

YTD

The  same  as  ENERGY  Mode,  press  the  [ 

Up  button

2

]  or  [ 

Down  but-

ton

3

] from the ENERGY HISTORY Mode will allow the user to view the 

data for each single channel.
10 seconds idleness on each channel display will return the LCD screen to 
ENERGY HISTORY Mode.

If the value of the history data is more 
than 9999, the digits will be displayed 
as  dashes  [ 

-  -  -  -

  ].  Upon  which  the 

user  can  press  the  [ 

Up  button

2

and  [ 

Down  button

3

]  at  the  same 

time to get the value after deducting 
10,000.
For  example,  if  the  YTD  value  is 
10,000  kWh,  the  user  will  get  the 
value of 0000 kWh. For 10,005 kWh, 
the user will see the difference value 
as 0005 kWh (as Fig. 20).

 

the  electricity  consumption  from  00:00  of  current  day  to 
now. 

 

the  electricity  consumption  from  00:00  1st  of  current  month 
to now.

 

the electricity consumption from 00:00 1st January of current 
year to now.

4 Mode of Energy Monitor

2  ENERGY Mode

From the COST Mode, shortly press the [ 

Set button

1

ONCE 

to switch 

to the ENERGY Mode (as Fig. 17), which displays the current power under 
consumption for all channels.

Fig. 17

Press ONCE

ENERGY Mode

10 sec

idleness

Fig. 18

Press the [ 

Up button

2

] or [ 

Down button

3

] from the ENERGY Mode 

will allow the user to view the power consumption for each single channel 
(as Fig. 18). In that case, the clock icon and numbers will be replaced by 
the channel number.
10 seconds idleness on each channel display will return the LCD screen to 
ENERGY Mode of all channels.

1

There are two units (watts and kW) involved in this Mode. For data equal 
to or below 999.9 watts, the unit displayed is watts, for data over 999.9 
watts, the unit will automatically switch to kW (Fig. 18).

21

20

Summary of Contents for EW4008

Page 1: ...WIRELESS Energy Monitor Monitor household electricity use Instruction Manual EW4008 C Tx Rx...

Page 2: ...batteries Do not use the monitoring system if you find your electric wire in abnormal conditions such as loose wire exposed copper wire burnt mark on wire insulation layer holes on wire layer or dama...

Page 3: ...re available to purchase online and your reseller Please visit www wattsclever com C Tx Rx C Tx Rx Contents 5 6 7 16 18 19 20 21 23 25 27 28 29 30 Contents of the box Parts Setup 1 Full LCD Display La...

Page 4: ...display will shown the default setting for the year is 2011 and the symbol Y is flashing Fig 2 Now press the Set button1 shortly Fig 2 The thousand digit will flash Then use Up button2 or Down button...

Page 5: ...DAY press Down button3 To modify the DAY please press the Set button1 again to restart the DAY setting Setup Press Set button1 to confirm and you will see that the hundred digit of the year begins to...

Page 6: ...e the complete voltage value flash Fig 8 The voltage are generally in the range 100 240V Check carefully the voltage level of your country before set up Setup Step 5 Setting Mode Setup for the TIME Af...

Page 7: ...ress the Set button1 to confirm for the rate of TARIFF 1 Setup To modify the CURRENCY please press the Set button1 again to restart the CURRENCY setting Step 7 Setting Mode Setup for the CURRENCY Afte...

Page 8: ...g 11 follow by TARIFF 3 Please operate the setting same way as Setting of Tariff 1 symbol is flashing behind TARIFF Setup Press the Set button1 shortly the hour value of the clock will flash Use the U...

Page 9: ...its value will disappear to be replaced by the channel numbers After adjusting to the desired channel We recommend use CH 01 for mon itoring entire house energy consumption press the Down button3 and...

Page 10: ...ny other displays will return the LCD screen to the COST Mode 10 sec idleness Fig 16 COST Mode Setup 4 Installation of the Power Transmitter OR Fig 15 You may choose to put the Power Transmitter in a...

Page 11: ...ser will get the value of 0000 kWh For 10 005 kWh the user will see the difference value as 0005 kWh as Fig 20 the electricity consumption from 00 00 of current day to now the electricity consumption...

Page 12: ...same time to get the value after deducting 10 000 For example if the YTD value is 10 000 the user will get the value of 0000 For 10 005 the user will see the difference value as 0005 as Fig 24 4 Mode...

Page 13: ...nto the history date input interface as Fig 25 Fig 25 Press for 3 sec The first two digits represent Month range 01 12 and the last two digits represent Date range 01 31 If you want to view the histor...

Page 14: ...s a BEE sound In Fig 29 bON is the screen symbol of buzzer on status After switching to desired status press the Set button1 to finish the set ting and return to the COST Mode COST Mode Fig 28 Buzzer...

Page 15: ...Mauritius Montserrat Leeward Is Myanmar formerly Burma Nepal Netherlands New Zealand Norway Poland Portugal Romania Rwanda St Kitts and Nevis Leeward Is St Vincent Windward Is Samoa Senegal Sierra Le...

Page 16: ...e household ap pliances Television Toaster Air conditioner Hot water heater Microwave 150 W 1000 W 2000 5000 W 4000 W 1000 2000 W My Appliances Cost Dishwasher Electric stove Microwave Clothes washer...

Page 17: ...CD Display 79 L x 48 5 H mm Power Transmitter 90 5 L x 72 W x 44 5 H mm Operating range 80 265V Wireless transmission 433 MHz SRD band Maximum rated sensor current 100A Min current sensitivity 0 1A Ma...

Reviews: