4
Rear Panel
A. Power Inlet:
For a 3-prong IEC power cord.
B. Circuit breaker:
10A resettable breaker that trips when over amperage conditions occur. Press to reset.
C. Bonding Point:
Post for bonding equipment.
D. Controllable outlets 1-8:
All outlets are filtered against EMI/RF and individually switchable (IP controlled).
E. Power indicators for outlets 1-8:
Illuminates when power is on (x8 – 1 for each outlet).
F. Reset button:
Press and release to restart the network card, press and hold five seconds to reset network settings,
and press and hold 10 seconds to restore to factory defaults.
G. Safe Voltage button:
Toggles the
Safe Voltage
feature on and off. When enabled, Safe Voltage turns off outlets to
protect connected equipment from out-of-range input voltage.
H. UPS Link:
For future use to connect a WattBox OvrC-enabled UPS.
I. ACC port:
Accessory port for future use.
J. Network port:
Connect to the local area network (LAN) for IP control and monitoring.
240V
AC 60Hz
A
B
D
E
F
G
H
I
J
C