Watson McDaniel HSP Series Installation & Maintenance Manual Download Page 13

 

 

13 

Watson McDaniel Company         HSP Valve Manual Rev3 2415800 

 

 

Reduced Port 

Regulating Valve - Capacities 

 

  

  

  

  

  

  

  

  

  

  

  

  

  

 
 

 

REDUCED PORT CAPACITIES

 - (Steam lbs/hr)

 

Inlet 

Pressure 

(PSIG) 

Outlet 

Pressure 

(PSIG) 

1" 

1-1/2" 

2" 

3" 

4" 

Inlet 

Pressure 

(PSIG) 

Outlet 

Pressure 

(PSIG) 

1" 

1-1/2" 

2" 

3" 

4" 

CV Factors 

5.6 

13.3 

18.8 

41.7 

74 

CV Factors 

5.6 

13.3 

18.8 

41.7 

74 

  

  

  

  

  

  

90 

45 

916 

2177 

3077 

6825 

12112 

59 

140 

197 

438 

777 

60 

789 

1874 

2648 

5874 

10425 

53 

128 

181 

401 

712 

75 

585 

1389 

1964 

4357 

7731 

82 

195 

276 

613 

1088 

100 

50 

1018 

2419 

3419 

7584 

13458 

79 

187 

265 

587 

1042 

60 

940 

2234 

3158 

7006 

12432 

74 

177 

250 

554 

983 

80 

706 

1676 

2367 

5254 

9324 

10 

117 

279 

395 

876 

1554 

125 

60 

1290 

3063 

4329 

9603 

17041 

115 

274 

387 

858 

1523 

75 

1176 

2793 

3948 

8757 

15540 

102 

242 

342 

758 

1346 

100 

882 

2095 

2961 

6568 

11655 

12 

141 

335 

473 

1051 

1865 

150 

75 

1527 

3628 

5128 

11376 

20187 

133 

316 

446 

990 

1758 

100 

1315 

3123 

4414 

9791 

17374 

115 

272 

385 

854 

1515 

125 

975 

2316 

3274 

7261 

12885 

  

173 

410 

580 

1287 

2284 

175 

85 

1800 

4272 

6939 

13396 

23771 

15 

166 

395 

558 

1238 

2198 

125 

1440 

3421 

4835 

10725 

19032 

  

149 

354 

500 

1111 

1972 

150 

1060 

2518 

3558 

7893 

14008 

  

227 

541 

764 

1696 

3009 

200 

100 

2037 

4838 

6838 

15168 

26916 

20 

10 

204 

483 

684 

1517 

2692 

125 

1836 

4360 

6164 

13672 

24262 

  

12 

188 

447 

632 

1401 

2486 

150 

1556 

3695 

5223 

11584 

20557 

  

282 

670 

948 

2102 

3730 

225 

120 

2238 

5360 

7514 

16667 

29577 

25 

10 

269 

640 

905 

2006 

3561 

150 

1972 

4684 

6621 

14686 

26061 

  

15 

235 

559 

790 

1751 

3108 

175 

1663 

3950 

5583 

12384 

21976 

  

12 

323 

768 

1085 

2408 

4273 

250 

130 

2511 

5964 

8431 

18700 

33184 

30 

15 

305 

726 

1025 

2275 

4037 

150 

2352 

5586 

7896 

17514 

31080 

  

20 

263 

625 

883 

1958 

3475 

200 

1764 

4190 

5922 

13136 

23310 

  

18 

420 

998 

1410 

3128 

5551 

300 

160 

3015 

7160 

10120 

22450 

39840 

40 

25 

367 

872 

1232 

2734 

4852 

175 

2865 

6800 

9615 

21330 

37850 

  

30 

311 

739 

1044 

2317 

4111 

200 

2625 

6235 

8810 

19545 

34680 

  

20 

539 

1280 

1809 

4013 

7121 

350 

175 

3560 

8280 

2450 

25360 

45020 

50 

30 

470 

1117 

1579 

3502 

6216 

225 

3370 

7850 

10830 

24020 

42650 

  

40 

353 

838 

1184 

2627 

4662 

325 

3000 

6970 

9630 

21360 

37910 

  

30 

611 

1451 

2051 

4550 

8074 

400 

200 

4070 

9460 

2450 

28980 

51450 

60 

35 

573 

1361 

1924 

4268 

7573 

250 

3860 

8970 

12380 

27460 

48750 

  

50 

390 

926 

1309 

2904 

5154 

300 

3430 

7970 

11010 

24410 

43330 

  

35 

780 

1853 

2619 

5809 

10308 

450 

225 

4580 

10650 

2450 

32600 

57890 

75 

50 

657 

1561 

2207 

4895 

8687 

300 

4340 

10090 

13930 

30890 

54840 

  

60 

529 

1257 

1777 

3941 

6993 

350 

3860 

8970 

12380 

27460 

48750 

Note: For inlet pressures in shaded area, use low pressure main valve. 

 
 
 

Summary of Contents for HSP Series

Page 1: ...SP Pressure Pilot Regulating Valve Installation Operations Maintenance Manual 428 Jones Boulevard Limerick Airport Business Center Pottstown PA 19464 Phone 610 495 5131 Fax 610 495 5134 www watsonmcda...

Page 2: ...ing no load to Spring Based on approximate position of plug Each Watson McDaniel Company Product is warranted against defects in material and workmanship for one year from date of shipment This warran...

Page 3: ...Pilot Diaphragm which opens the Pilot Valve 4 The steam then travels through the Pilot Valve to the External Transmission Tubing This then fills the area under the Main Valve Diaphragm 5 T he pressure...

Page 4: ...uld be installed prior to the regulator 5 A strainer with blow down valve is recommended before all regulator installations The strainer should be in the horizontal position to prevent any collection...

Page 5: ...recommended to be installed in the sensing line for fine tuning purposes Start up 1 All valves in the installation need to be closed 2 Loosen the locknut on the pilot adjusting screw and back out unti...

Page 6: ...blow down and readjust if necessary Note At a minimum these maintenance operations should be performed a few days after the valve has been initially installed and shortly after the start up during eac...

Page 7: ...Upper Spring Button Stainless Steel 21 Cap Screws Steel 22 Spacer Steel B Pressure Pilot Service 1 Turn the pilot adjusting screw counter clockwise to remove all compression from the pilot spring 2 Sh...

Page 8: ...Body Steel 2 Cover w Bushing Steel 3 Diaphragm Cover Steel 4 Pilot 5 Seat Stainless Steel 6 Stem Disc Assembly Stainless Steel 7 Diaphragm Bronze 8 Cover Bolts Steel 9 Cover Nuts Steel 10 Spring Stain...

Page 9: ...screw for the diaphragm plate and then remove plate itself Caution The main valve spring is exerting significant force on the diaphragm plate Proceed slowly 10 Remove the top cover nuts and cover plat...

Page 10: ...by backing out the adjustment screw until there is no compression on the spring 3 Disconnect the pilot tube at the regulator diaphragm which is indicated as point A in the illustration above Also disc...

Page 11: ...e open b Close valve c Pilot valve adjusting spring set too high c Readjust to desired reduced pressure d Bleed orifice blocked d Inspect and clean e Dirt in pilot seat or stem guide e Clean pilot hea...

Page 12: ...100 4000 6400 200 100 4200 8000 14100 27100 43100 20 10 550 1000 1800 3500 5600 125 3700 7100 12600 24100 38400 12 500 950 1600 3200 5100 150 3100 6000 10600 20300 32300 7 775 1500 2600 5000 7900 225...

Page 13: ...1696 3009 200 100 2037 4838 6838 15168 26916 20 10 204 483 684 1517 2692 125 1836 4360 6164 13672 24262 12 188 447 632 1401 2486 150 1556 3695 5223 11584 20557 7 282 670 948 2102 3730 225 120 2238 53...