OPERATING CONDITIONS: 
 
MAX. INLET PRESSURE    250 PSIG 
MIN. INLET PRESSURE      5 PSIG 
MAX. DIFF. PRESSURE      125 PSIG 
MIN. DIFF. PRESSURE        20% of inlet pressure 

1/2"

 

-

 

1

 

1/2"

 

SERIES

 

455

  

INSTRUCTIONS:

  

S

TEM 

P

ACKING 

R

EPLACEMENT

 

 

1.)  

Isolate Series 455 from all system pressure.  It will be necessary to remove the 
bracket because the packing is endless.  Back off the bracket locknut and unscrew 
stem from end of diaphragm stem. 

 
2.)  

Remove the actuator-bracket assembly from the valve. 

 
3.)  

Reach down along the Stem with a picking device to pull out all the old Packing 
Rings.  Be careful not to scratch or gouge any of the sealing surfaces. 

 
4.)  

Push the new Packing Rings into place.  

 
5.)  

Slide Spring into place and hand tighten the Packing Nut. 

 
6.)  

Reinstall the bracket-actuator assembly to the stem and valve. 

 
7.)  

Bring the regulator back on line. 

 

 
 

 
  

 

 

 

 

 

 

 

 

 