15.2.9 Channel-related diagnostic data
Channel-related diagnostic blocks are always three bytes long in following format:
Channel-related diagnostic block format
Byte 26
Header
Byte 27
Channel type
Byte 28
Channel-related error code
Channel-related diagnostic data
Channel-related diagnostic data
Byte 3
Global error
=0xA9 (General error)
Over current
=0xA1 (Short circuit)
Under voltage
=0xA2 (Under voltage)
Over voltage =0xA3 (Over voltage)
=0xA3 (Over voltage)
Motor stall
=0xA4 (Overload)
Over temp =0xA5 (Over temp)
=0xA5 (Over temp)
Tacho fault
=0xB1 (Device related 0x11)
Leak detected
=0xB2 (Device related 0x12)
Fluid level alert
=0xB3 (Device related 0x15)
Reserved
=0xA6 (Reserved)
Setpoint out of range- high
=0xA7 (Upper limit exceeded)
Setpoint out of range- low
=0xA8 (Lower limit exceeded)
15.2.10 Device-related diagnostic data
Device-related diagnostic data
8 bit
Byte 1
Header Byte
16 bit
Byte 2, 3
Reserved
16 bit
Byte 4, 5
Reserved
16 bit
Byte 6, 7
Min Speed (unsigned)
16 bit
Byte 8, 9
Max Speed (unsigned)
32 bit
Byte 10, 11, 12, 13
Software Version Main CPU
32 bit
Byte 14, 15, 16, 17
Software Version HMI CPU
32 bit
Byte 18, 19, 20, 21
Software Version Flash
32 bit
Byte 22, 23, 24, 25
Software version PROFIBUS CPU