Watson-Marlow 720UN and 720SN User Manual
21
UN
720UN: First-time start-up defaults
Language
Not set
Analogue input
4-20mA
Speed
300 rpm
User trim
None
Direction
Clockwise
Remote stop
Open=run
Pumphead
720R
Scrolling increment
0.1rpm
Tube size
25.4mm
Output 1
Run/Stop *
Calibration
720R 25.4mm tube
Output 2
Direction †
Backlight
On
Output 3
Auto/Man ‡
Keypad lock
Off
Output 4
General alarm
Auto-restart
Off
Pump status
Stopped
Beeper
On
* Run
= high
Manual screen
rpm
† Clockwise rotation
= high
Security code
Not set
‡ Auto
= high
Note
: The settings shown above for Run, Clockwise rotation and Auto are those in
force on initial start-up for the functions available on Output 1, Output 2 and Output
3 respectively. For example, a high signal on Output 2 indicates clockwise rotation.
These can be changed later according to user requirements.
Note
: High is equivalent to the common and normally open contacts of the relay on
the module board being closed.
720SN: First-time start-up defaults
Language
Not set
Keypad lock
Off
Speed
300rpm
Auto-restart
Off
Direction
Clockwise
Pump status
Stopped
Pumphead
720R
Beeper
On
Tube size
25.4mm
Manual screen
rpm
Calibration
720R 25.4mm tube
Scrolling increment
0.1rpm
Backlight
On
SN
UN, SN
The pump is now ready to operate according to the defaults listed above.
All operating parameters may be changed by means of key-presses. See 14
Manual
operation
.