8
Installation
Remove the top half casing from the drive. Pass the switched guard wires on the track through the front panel of the
drive and connect to the terminal blocks. Replace horizontal, front and back panel case gaskets to ensure the IP55
ingress protection standard is not compromised. Replace top half casing.
1
Red
2
Black
3
Red
4
Yellow
5
Black.
Fit the track over the drive shaft and locating boss. Secure the track with the retaining screws. Ensure the drive shaft
has been completely degreased before locating the rotor onto the shaft via a split collet. Tighten the rotor bolt to a
torque of 13Nm to prevent the collet slipping during operation.
•
Pump shown in track loading pictures is the 603S/R
To remove the track, remove any tubing from the pumphead. Loosen the rotor securing bolt and give the rotor/bolt a
sharp tap to free the collet. Release the collet, and withdraw the rotor from the shaft. Loosen the two track securing
screws and pull the track clear. Use this method of removal and fitting in case cleaning is required.
Summary of Contents for 604U
Page 1: ...604U 604u gb 02 pdf...
Page 12: ...12 Outline dimensions...