Calibration procedure 

Ensure the correct wiring of the 6 pin plug and insert the plug into the socket at the rear of the pump. 

• 

Remove the rear panel window. 

• 

Turn the signal offset potentiometer clockwise until the slider traverse limit is reached and is signified by a clicking 
noise. Now        turn the potentiometer ten turns anticlockwise. Repeat for the signal range potentiometer. This 
ensures correct potentiometer set-up for calibration. 

• 

Set the process signal offset.   

• 

Turn the signal offset potentiometer clockwise to set the drive shaft speed to the desired minimum. 

• 

Set the process signal at its upper range limit (not exceeding 30V or 32mA). 

• 

Turn the signal range potentiometer clockwise to set the drive shaft speed to the desired maximum.  

• 

Repeat the procedure until pump response coincides exactly with the process signal. 

• 

If the signal rises above its designated maximum, the action of the signal conditioner will be to hold the motor to 
maximum speed at the MAX setting indicated by the LED indicator flashing. If the signal rises above 30V, 
permanent damage, not covered by warranty, may result.  

 

 

Securely replace the rear panel recess cover on the back of the pump ensuring the gasket is in 
the correct position. This will avoid the ingress protection standard of the pump being 
compromised

 

 
Remote control 

Stop/Start

 

Connect remote switch between pins 2 and 5 of the 6 pin socket. Close contact to stop the pump, open to run.  

 

Speed

 

A remote potentiometer with a nominal value of between 4.7kohm and 5kohm should be wired as shown, When using 
a remote potentiometer do not connect a voltage/current control signal at the same time. The speed control signal will 
require calibration relative to the minimum and maximum settings of the potentiometer. Use the offset and range 
potentiometers as described under calibration. 

 

Tachometer output 

This facility can be used to indicate motor speed or total the number of motor revolutions. Select either 1) 0-5V DC or 
2) 5V pulse train output using the tachometer output switch. 

• 

3.45kHz at 165rpm 

• 

0.07kHz at 3.3rpm 

 

Summary of Contents for 604U

Page 1: ...604U 604u gb 02 pdf...

Page 2: ...ss permission of Watson Marlow Limited its subsidiaries or its authorised distributors Products which have been abused misused or subjected to malicious or accidental damage or electrical surge are ex...

Page 3: ...s is to counteract the normal stretching that occurs with Marprene which can go unnoticed and result in poor tube life Tube selection The chemical compatibility list published in the Watson Marlow cat...

Page 4: ...otation The preferred direction of rotation is clockwise with fluid entering at the bottom of the pumphead which will ensure the longest possible tube life To operate against higher pressures use anti...

Page 5: ...l level which has to be reached in order for the pump rotor to start rotating Signal range is the change in process signal level necessary to produce the required change in pump rotor speed For exampl...

Page 6: ...ld the motor to maximum speed at the MAX setting indicated by the LED indicator flashing If the signal rises above 30V permanent damage not covered by warranty may result Securely replace the rear pan...

Page 7: ...55 Machinery Directive 98 37 EC EN60204 1 Low Voltage Directive 73 23 EEC EN61010 1 EMC Directive 89 336 EEC EN50081 1 EN50082 1 Specific drive performance details such as loaded drive speed variation...

Page 8: ...track with the retaining screws Ensure the drive shaft has been completely degreased before locating the rotor onto the shaft via a split collet Tighten the rotor bolt to a torque of 13Nm to prevent t...

Page 9: ...ot slack in the pumphead since this can reduce tube life Clamp the tube very firmly by turning the upper serrated adjustment wheel Remove the spanner and close the guard Roller adjustment Should it ev...

Page 10: ...0258M Guard 3 SW 0139 Guard Switch magnet 4 MR 0601T Collet 5 MR 0571T Roller tube 6 MR 0575T Roller tube guide 7 MR 0573T Spindle 8 MRA0010A Rotor assembly 9 SG 0003 Spring 10 MR 0572T Roller guide...

Page 11: ...Terminal block 5 UP 0035 6 pin plug 18 MR 0691S Gasket 6 US 0035 6 pin socket 19 OS 0042 Seal O ring 7 FA 0010 Earth filter 20 SW 0146 Auto man max 8 MR 0669S Cover plate 21 MR 0769B Potentiometer 9 M...

Page 12: ...12 Outline dimensions...

Page 13: ...ach pump returned RGA No 1 Company Address Postcode Telephone Fax Number 2 1 Serial Number One product per declaration 2 2 Has the Product been used Yes No If yes please complete all the following Sec...

Reviews: