Batch name
The batch name gives the user a convenient way to identify a batch.
Maximum 12 characters. (A-Z, 0-9).
•
Using the
∧
/
∨
keys, enter a character.
•
Press
NEXT
to confirm your character and to move onto the next. Press
PREVIOUS
to move
the cursor back one character.
•
Move the cursor to the end or beginning of the entry field using
NEXT
or
PREVIOUS
. When the
cursor is at the beginning or end of the entry field, press
FINISH
to store the entry.
Batch size
Enter the number of fills to be completed in the batch.
•
Minimum - 1
•
Maximum - 999999
Press
∧
/
∨
to scroll to less than 1 or above 999999 to select UNLIMITED batch size. The pump will
continue to dispense until it is stopped by the user.
Active recipe
The recipe that will be used for this batch.
Direction
The pump may be set up so that the direction of rotor rotation is clockwise or counter-clockwise,
whichever is required.
Please note, however, that for some pumpheads the tube life will be greater if the rotor rotates
clockwise; and that performance against pressure will be maximised if the rotor rotates counter-
clockwise. To achieve pressure in some pumpheads the pump must rotate counter-clockwise.
Start delay (batch)
Sets time delay between start signal and first dispense start of the batch.
Refer to "Dispense time delays diagram" on page 110.
End delay (batch)
Sets time delay at the end of the batch.
Refer to "Dispense time delays diagram" on page 110.
Recipes
A
recipe
contains all the parameters for the required dispense. The active recipe must be selected
when editing the batch before the dispense can be started. Therefore you must have at least one
recipe to start Dispense.
Recipe parameters
Configure the following parameters:
m-530pn-en-09 02-02-22