Watson Marlow Pumps 504S Manual Download Page 13

13

Product use and decontamination declaration

In compliance with the 

UK Health & Safety at Work Act

 and the

 Control of Substances

 

Hazardous to Health

Regulations

 you, the user are required to declare the substances which have been in contact with the product(s) you

are returning to Watson-Marlow or any of its subsidiaries or distributors. Failure to do so will cause delays in servicing
the product. Therefore, please complete this form to ensure that we have the information before receipt of the
product(s) being returned. A FURTHER COPY 

MUST

 BE ATTACHED TO THE OUTSIDE OF THE PACKAGING

CONTAINING THE PRODUCT(S). You, the user, are responsible for cleaning and decontaminating the product(s)
before returning them.

Please complete a separate Decontamination Certificate for each pump returned. 

RGA No:

 …………………...

1 Company

  Address ……… ................................................................... Postcode ………………………………………

  Telephone ……………………………………………. ................. Fax Number …………………………………..

2.1 Serial Number … … … … … … … … … … … … … ........... (a)………………………………………………….

2.2 Has the Product been used?

(b)…………………………………………………

YES

NO

                                        (c)…………………………………………………

              

                                                                          (d)…………………………………………………

If yes, please complete all the following Sections. If no, please complete Section 5 only

3 Details of substances pumped

3.1 Chemical names:

(a)………………..........................

(b)…………….............................

(c)………………..........................

(d)…………….............................

4 I hereby confirm that the only substances(s) that the equipment specified has
pumped or come into contact with are those named, that the information given is
correct, and the carrier has been informed if the consignment is of a hazardous
nature.

5 Signed …………………………………………………………………………………

  Name  …………………………………………………………………………………

  Position ……………………………………………………………………………….

  Date …………………………………………………………………………………..

3.2 Precautions to be taken in handling these substances: 

To assist servicing, please describe any fault

(a)………… ....................................................

condition(s) you have witnessed

(b)…………  ...................................................

…………………………………………………

(c) ………………...............................................

……………………………………………………………

(d)………………................................................

……………………………………………………………

3.3 Action to be taken in the event of human contact:

……………………………………………………………………………………………………

(a)………………………………………………………………….

……………………………………………………………

(b)………………………………………………………………….

……………………………………………………………

(c)………….………………………………………………………

……………………………………………………………

(d)………….………………………………………………………

……………………………………………………………

3.4 Cleaning fluid to be used if residue of chemical is found:

……………………………………………………………

(a)…………………………………………………………………. 

……………………………………………………………

(b)…………………………………………………………………. 

……………………………………………………………

(c)………….………………………………………………………

……………………………………………………………

(d)………….……………………………………………………… 

……………………………………………………………

Watson-Marlow Bredel Pumps . Falmouth . Cornwall TR11 4RU . England . Tel: 01326 370370 . Fax: 01326 376009

Summary of Contents for 504S

Page 1: ...504S 504s gb 03 pdf...

Page 2: ...ord with the terms of this warranty shall not be binding upon Watson Marlow Limited unless expressly approved in writing by a Director or Manager of Watson Marlow Limited Information for returning pum...

Page 3: ...should be run only while its feet are standing on a horizontal surface The pump should be positioned to allow a free flow of air around it Remove the small transparent plate on the rear panel to gain...

Page 4: ...rs at maximum speed If the pump requires cleaning use a mild solution of detergent in water after removing the pumphead Do not use strong solvents For gearbox rebuilds use 15ml of the recommended lubr...

Page 5: ...out the rotor crank handle until it locks into position Select the length of tubing required noting that approximately 240mm is required for the track systems Fit one end of the tubing into one of th...

Page 6: ...oth rollers are just touching the track then tighten each screw by three and a quarter turns The 501RL2 has a factory set gap of 3 8mm between the wall and the track and is suitable for tubing having...

Page 7: ...488S MN 0488S Front rear panel gasket 7 MN 0487S MN 0487S Top bottom case gasket 8 BM 0014 BM 0012 Motor brush 9 MNA0388A Geared motor 220rpm 9 MNA0396A Geared motor 55rpm 9 MNA0459A Geared motor 170r...

Page 8: ...8 Outline dimensions...

Page 9: ...9 6 1 16 1 8 3 16 1 4 5 16 3 8 55 40 125 230 385 495 685 220 155 500 925 1540 1980 2750 505BA ml min Flow rates mm 0 13 0 005 0 19 0 007 0 25 0 01 0 38 0 015 0 50 0 02 0 63 0 025 0 76 0 03 55 0 027 0...

Page 10: ...2 0 112 13 14 16 25 17 18 112 13 14 16 25 17 18 mm 0 5 0 8 1 6 3 2 4 8 6 4 8 0 0 5 0 8 1 6 3 2 4 8 6 4 8 0 1 50 1 32 1 16 1 8 3 16 1 4 5 16 1 50 1 32 1 16 1 8 3 16 1 4 5 16 55 6 6 6 6 6 4 3 6 6 6 6 5...

Page 11: ...965 0064 016 920 0064 016 950 0064 016 8 0 5 16 18 960 0080 016 960 0080 016 920 0080 016 950 0080 016 mm Fluorel Butyl 1 6 1 16 14 970 0016 016 930 0016 016 3 2 1 8 16 970 0032 016 930 0032 016 4 8 3...

Page 12: ...E080 024 913 E080 024 902 E080 024 960 E080 K24 965 E080 K24 9 6 3 8 122 910 E096 024 913 E096 024 902 E096 024 9 6 3 8 122 910 H096 024 high flow element 501RL Flow rates Watson Marlow Bioprene and...

Page 13: ...tion Certificate for each pump returned RGA No 1 Company Address Postcode Telephone Fax Number 2 1 Serial Number a 2 2 Has the Product been used b YES NO c d If yes please complete all the following S...

Reviews: