FIREROD® Product Guide

Notes:

1)  Above depictions represent the basic protection requirements in a simple circuit.
2)  Multiple heating elements may be wired in series or parallel.
3)  Heating elements considered “live” must be isolated from protective ground circuit.

The tables below list standard specifications for the preferred lead wires for the product. 

Note:

 not all lead wire  

options are shown below, please reference descriptions in your quote and/or purchase order for additional or 
non-standard lead wire specifications.

Note:

 lead wires should not be assumed to be agency recognized unless marked as such. Contact your Watlow 

representative if you have further questions. 

 

Product Size Designation

Heater Sheath Nominal Outer Diameter

3.1 < 9.4 mm

(

1

/

8

 - 

5

/

16

 in.)

9.4 < 12.6 mm

(

3

/

8

  and 

7

/

16

 in.)

12.6 < 15.8 mm 

(

1

/

2

  and 

9

/

16

 in.)

≥ 15.8 mm

(≥ 

5

/

8

  in.)

 Fiberglass insulated

24 Ga. MGT 300V 22 Ga. MGT 300V 18 Ga. MGT 300V 18 Ga. MGT 600V

PTFE insulated

24 Ga. black 

PTFE 300V

22 Ga. black 

PTFE 300V

18 Ga. black 

PTFE 300V

14 Ga. black 

PTFE 600V

Minimum Recommended Circuit Requirements

(AC - Three Phase Delta)

Standard/Default Lead Wires

Product Size Designation

Heater Sheath Nominal  

Outer Diameter

3.1 < 9.4 mm

(

1

/

8

 - 

5

/

16

 in.)

9.4 < 12.6 mm

(

3

/

8

  and 

7

/

16

 in.)

12.6 < 15.8 mm 

(

1

/

2

  and 

9

/

16

 in.)

≥ 15.8 mm

(≥ 

5

/

8

  in.)

Alternate

≥ 15.8 mm

(≥ 

5

/

8

  in.)

 Recognition

UL

®

 5128 / CSA

UL

®

 5107 / CSA

Max voltage

300 Volts

600 Volts

Strands

7/32

7/30

7/26

7/26

41/30

Design description

24 Ga. MGT  

nickel leads

22 Ga. MGT  

nickel leads

18 Ga. MGT  

nickel 300V

18 Ga. MGT  

nickel 600V

14 Ga. MGT  

nickel leads

Max amperage

3.1

4.4

7.6

7.6

12.5

Design description

24 Ga. MGT NCC 

leads

22 Ga. MGT NCC 

leads

18 Ga. MGT NCC 

300V

18 Ga. MGT NCC 

600V

14 Ga. MGT NCC 

leads

Max amperage

5.2

7.2

12.6

12.6

21.0

Fiberglass Lead Wire Specifications

MGT fiberglass lead wire maximum temperature = 842°F (450°C)

Minimum Circuit Requirements (Con’t)

Summary of Contents for FIREROD

Page 1: ...product is properly selected and installed in accordance with applicable recommendations given within this guide Note this guide does not cover all foreseeable end use applications therefore consult y...

Page 2: ...pre check During shipping and or storage the possibility of moisture absorption by the insulation material within a heater element is possible To determine if the proper megohm value is present use a...

Page 3: ...ure control protection in systems where an over temperature fault condition could cause a fire or other hazard Failure to install temperature control protection where such a hazard exists could result...

Page 4: ...mains line voltage applied to the product must always be equal to or less than the voltage rating marked on the product s name plate label Some heaters are supplied as dual voltage e g 240V 480V unit...

Page 5: ...mm 5 8 in Fiberglass insulated 24 Ga MGT 300V 22 Ga MGT 300V 18 Ga MGT 300V 18 Ga MGT 600V PTFE insulated 24 Ga black PTFE 300V 22 Ga black PTFE 300V 18 Ga black PTFE 300V 14 Ga black PTFE 600V Minimu...

Page 6: ...1 8 5 16 in 9 4 12 6 mm 3 8 and 7 16 in 12 6 15 8 mm 1 2 and 9 16 in 15 8 mm 5 8 in Recognition UL 1815 CSA UL 1659 CSA Max voltage 300 Volts 600 Volts Strands 7 32 7 30 7 26 19 27 Design description...

Page 7: ...less than one megohm Refer to megohm pre check in the Installation section of this guide Not enough power application not heating to desired temperature Verify line voltage is within specification If...

Page 8: ...may be found attached to any order acceptance or bid prepared by Watlow For a copy of such terms and conditions please contact Watlow s customer service department or visit our website http www watlow...

Reviews: