FILTER MOUNT MUST:

 

•   Provide weather and freezing protection. 

 

•   Provide space and lighting for easy access for routine    

 

 maintenance. 

 

•   Provide ventilation and drainage for pump. 

 

•   Be on a reasonably level surface and provide adequate    

 

 drainage.

PIPING: 

NOTICE:

 Make sure that the filter and all piping can be drained for 

winterizing. See “Winterizing”, page 8.

NOTICE:

 Overtightening can crack filter ports.

Use Teflon tape, Plasto-Joint Stik®

 or Silastic RTV #732® on all threaded 

connections of plastic pipe and fittings.

DO NOT use pipe compounds on filter; it will cause the 
connection to crack. Do not use sealant on unions; assemble 
them dry and hand tight.

Support pipe independently to prevent strains on the filter.
Keep piping tight and free of leaks. Pump section line leaks may cause 
trapped air in filter tank or loss of prime at pump.

† Lake Chemical Co., Chicago, Ill.

ELECTRICAL:

Be sure that pump grounding meets local and National Electrical Code 
Standards. All wiring and grounding of associated equipment must 
meet local and National Code Standards.

INITIAL START-UP

Be sure pump is OFF before starting procedure.
Do not operate filter at more than 50 PSI (345 kPa).

1. Securely lock the Pro-Clean Ring in place by rotating it CLOCKWISE  
  until it “clicks” past the safety latch (see Figure 3). Stop turning as    
  soon as the ring clicks past the latch. The ring may feel slightly  
  loose, but it will tighten up when the pump is on and the filter is    
  under pressure.
2. Install the pressure gauge and the air release valve (see Figure 2) on  
  the tank lid.
3.  Fill the trap on the pump with water.
4. Open the air release valve on top of the filter.

5. Open valves separating the filter from the rest of the system.
6. Start the pump to purge air from the system.
7. When a steady stream of water comes from the air release valve,    
  close the valve.

NOTICE:

 Leaking around the filter ring may indicate that the ring is not 

fully locked. In this case proceed as follows:
    A. Stop the pump and open the air release valve then release    
      any pressure within the filter.
    B. Remove the drain plug and drain all water from the filter.
    C. Rotate the filter ring clockwise until it locks behind the  

 

      safety latch (see Figure 3).
    D. If the ring was already locked, remove it and the filter lid  

 

      assembly. Inspect and clean the O-ring and all sealing surfaces.  
      Re-lubricate the O-ring, if necessary.

NOTICE:

 Lubricate the O-ring sealing area inside the upper tank lip 

with silicone grease, as other lubricants may cause the ring to swell. DO 
NOT lubricate the filter ring or the threads on the tank shell as this may 
collect grit and make removal difficult.

Figure 2

Air Relief 

Valve

Pressure

Gauge

Filter Ring

Latch

Summary of Contents for pro clean plus

Page 1: ...nstallation Operation Parts 810 0183 N 0618 2018Waterway Plastics 2200 East Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 www waterwayplastics com waterway waterwayplastics com Desi...

Page 2: ...FILTERS Pre assembled filter Position of tube in body Install pressure gauge following Start Service Dial Installation Instructions in separate bag inside fitting package Position of cartridge and tu...

Page 3: ...nd Place pump on base 2 Attach pump to base with included screw 3 Place filter inside base Wrap 3 or 4 turns ofTeflon tape on 2 tailpiece and thread into inlet in filter DO NOT insert snap pins throug...

Page 4: ...thread onto 2 x 1 1 2 MPT union fitting NOTE Do not putTeflon tape on adapter threads to gate valve Place gasket in split nut 4 Make sure gasket is in place on elbow assembly and install onto tailpie...

Page 5: ...ncreases 10 PSI over the start up pressure In some pools accessories such as fountains or pool cleaners may be noticeably affected by the normal decrease in flow as the filter becomes dirty If so clea...

Page 6: ...KWISE until it clicks past the safety latch see Figure 3 Stop turning as soon as the ring clicks past the latch The ring may feel slightly loose but it will tighten up when the pump is on and the filt...

Page 7: ...nk shell threads and rotate it CLOCKWISE until it is securely latched 5 Follow instructions in the Initial Startup section of this manual SAFETY LATCH The purpose of the safety latch is to hold the fi...

Page 8: ...pool professional for recommendation B Filter cartridge is dirty or plugged thoroughly clean the filter see no 4 Plugged Cartridge and Cleaning Cartridge Procedure page 8 C Water is chemically out of...

Reviews: