WARNING! SHOCK HAZARD! NO USER SERVICEABLE PARTS.

 

Do not attempt service of this control system. Contact your dealer or service organization for assistance.    

 

Follow all owner’s manual power connection instructions. Installation must be performed by a licensed  

 

 

electrician and all grounding connections must be properly installed.

SERVICE MODE:

 to provide the spa service person and spa manufacturing more function capability in order to test, 

setup, or troubleshoot spa problems. This mode is intended for people with spa knowledge and therefore requires a 
special combination to enter.

}

 The user can access this mode through MENU > SERVICE MODE.

}

 With the SERVICE MODE highlighted, the user needs to press the MENU button, then press UP button, and finally  

 press 

DOWN button to enter SERVICE MENUS.

}

 The combination keys need to be entered within 5 seconds from the last button pressed, otherwise the sequence  

  needs to start over again.

}

 If a wrong button is pressed during the sequence, the combination key needs to start over.

}

 The following are functions available inside Service Mode:

  n

  

EQUIPMENT TEST:

 the equipment test or spa test is similar to Demo Mode, except the timing is longer. This is  

    used by manufacturing to test their spa system after it is put together in the final line.
    •  When user starts the equipment test:
    · MENU will exit to MAIN screen immediately
      · The system light and options (if selected in configuration) will turn on if not already on.
      · 5 seconds after light on, the first pump LOW is on
      · Every 1 minute following, the next pump LOW will turn on
      · One minute after all pump LOWS are on, the first pump LOW will switch to HIGH speed
      · Every 1 minute following, the next pump LOW will switch to HIGH speed and pump HIGH will set to run for 5  
       minutes
      · One minute after all pump HIGH are on, if the system has a blower and ozone then both blower and ozone  
        will turn on
      · Five minutes after all devices are turned on, all devices will get turned off, except the heat related pump will  
        switch to LOW speed.
      · Equipment test is finished
    •  After equipment test is completed, the system will do a poll to check for water temperature and take appropriate  
      action (Refer to 

Water Temperature Checking section for more detail)

  n

  

SYSTEM DEFAULT:

 allow the user to reset all user settings to default manufacturer’s settings

    • Reset USER setting can be done through selecting DEFAULT in this menu and pressing RETURN
    •  When executed, the controller will reset all user settable values from the user menu to default values from the  
    manufacturer 
    •  After resetting the values, the controller will reboot by itself and come back up in PRIMING MODE
    •  All values settable under service mode will not get reset and will stay the same

  n

  

SYSTEM LOGGED:

 ability to display the last 100 events that happened in the system. Through events logged,  

    service may be able to determine the root cause of the problem.
    •  Event shows date and time in one line and the event in the next line
    •  Due to the screen having an odd number of lines, the software needs two screens to display a completed 5  
      events. Therefore the user sees the first 2.5 events logged in one screen and another 2.5 events in another.
    •  The event logged displays in the order of last-in, first-out display
    • Push DOWN button twice to show the next 5 logged