Suction cover life is 7 years, the sump wall fitting life is 14 years, the rest of the components have 25 year life, cover and all  

  SOFA components shall be replaced on or before the end of service life. 

  The use of adhesives or other attachment methods that prevent access to suction piping or SOFA components is prohibited. 

  Please refer to Head Loss Curve, suction head measured at the wall fitting. 

  This is a blockable SOFA as marked on the suction cover. 

  Hand tighten screwsto 24 in-lbs torque, DO NOT USE POWER TOOLS TO INSTALL FASTENERS. Ensure proper thread engagement  

  to prevent cross-threading. 

  Ensure proper flatness of installation surface. 

• 

When mud-rings, sump and other components are held in place by the interior surface of the pool, the surface should be free  

  of deterioration or voids

  Damaged Fasteners shall be replaced with original parts, and must be grade 316 stainless steel. The wall fitting shall be  

  inspected for the presence of any CRACK or material loss. Cracked/damaged mud rings, sumps, or wall fittings shall  

  be  replaced.

  No unauthorized field modifications. 

  This product is intended for use on gunite, vinyl, fiberglass, and roto-molded pools, spas and hot tubs.

  No modification shall be made to SOFA structure or flow path unless the configuration has been certified as a new SOFA. 

  Service life begins the month and year in which SOFA components are installed with or without water. 

  For winterization remove the cover and plug the inlet. 

  Use screw driver for service and removal of fasteners. 

  Observe cover/grate/fasteners for damage each operational day. 

  During installation ensure components and fastener receptacles are clean, free of debris and obstructions. 

  Hand-check cover/grate for snugness to the sump/frame/wall fitting after installation. 

  SOFA installation components with crack, chunks, or pieces broken off, stripped screw holes, and/or unusual discoloration  

  should be replaced. 

  The mounting surface or interior surface of the pool should be free of deterioration.

  Start installation of screws by hand to ensure proper thread engagement and to prevent cross-threading. 

  Do not exceed the safe flow rating of SOFAs as listed. 

  All SOFAs should be installed in accordance with Waterway installation instructions.

  No modification shall be made to SOFA structure or flow path unless new configuration has been certified as a new SOFA. 

  Under no condition should SOFA special flow rating be exceeded while the pool is open. 

  The capacity of secondary circulation system (skimmer, cutters, etc) should not be included when evaluating an individual  

  suction system flow rating.

  For the flow rating for pools with multiple blockable SOFAs in one body of water without isolation valves: combine all SOFAs,  

  minus the flow rate of one, if all are not equal use the larger flow rate. 

  “Blockable” SOFAs in new pools shall be installed in multiple-SOFA system ONLY.

  “Blockable” SOFAs in existing pools with single SOFA systems shall be installed with an additional anti-entrapment device  

  or system.
 

Summary of Contents for 640-231 V Series

Page 1: ...ENUINE WATERWAY REPLACEMENT PARTS IMPORTANT SAFETY INSTRUCTIONS For Part Numbers 640 2310 640 2311 640 2312 640 2317 640 2319 DKG 640 2319 BEI 640 2319 DKB 810 0046 0121 2021 Waterway Plastics 2200 Ea...

Page 2: ...tion cover for service or winterization using a Phillips head screw driver remove the screws Inspect both the suction cover and suction fitting for any cracks or damages Any and all broken or missing...

Page 3: ...ter For winterization remove the cover and plug the inlet Use screw driver for service and removal of fasteners Observe cover grate fasteners for damage each operational day During installation ensure...

Page 4: ...2 3 1 819 00801 642 215x V 642 214x 2 3 1 819 00801 642 215x V SG642 214x 640 2310V SG6402310...

Page 5: ...SUMP DUAL PORT 3 1 2 672 2510 642 215x V 819 00801 4 715 9910 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE POWERTOOLS 3 A mini...

Page 6: ...COLLAR SUMP DUAL PORT 5 4 3 1 2 819 00801 642 215x V 642 2240 715 9910 672 2550 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE PO...

Page 7: ...RATED ANTI VORTEXVINYL LINER ASSEMBLY 1 Install rubber gasket to body by pushing in raised alignment cups into slots in body see Diagram A 2 Lay vinyl liner over main drain 3 Put fiber gasket and moun...

Page 8: ...DEEP SUMP DUAL PORT 3 4 1 2 819 00801 642 215x V 715 9930 672 2610 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE POWERTOOLS 3 A...

Page 9: ...LLAR DEEP SUMP DUAL PORT 4 5 3 1 2 819 00801 642 215x V 642 2240 715 9930 672 2650 GRATED ANTI VORTEX CONCRETE ASSEMBLY 1 Align cover holes with brass inserts 2 Hand tighten supplied screws DO NOT USE...

Page 10: ...642 2150 V 4 FLOW PATH 8 FLOW PATH POOL STRUCTURE FINISH SURFACE OF THE POOL FIELD BUILT DEEP SUMP WITH 2 5 PIPE SECTION A A A A SECTION A A 2 SOC 2 SOC 642 215X V 5 25 FLOW PATH 4 FLOW PATH FINISH S...

Reviews: