Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction 

outlets can result in an increased potential for suction entrapment as described on the previous page.

This fitting is rated at 178 GPM for floor mount and 132 GPM for wall mount. If the fitting is missing or broken, 

replace with a fitting of equivalent rating or higher. Use of a lower rated suction fitting could result in 

entrapment of the body which could result in serious injury including drowning.
Do not use or operate pool, spa, or hot tub if this suction fitting is missing, broken or not secured per 

instructions. The suction fitting is intended to prevent entrapment of the body. Use of the spa hot tub with a 

missing, broken or improperly secured suction grate may result in serious personal injury including drowning.
When the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must 

be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or 

hot tub blocks this fitting with his/her body, serious personal injury or drowning may occur.

Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material, 

can result in an increased potential for suction entrapment as described on the previous page.

Suction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at 

least every seven years, or if found to be damaged, broken, cracked, missing, or not securely attached.

WARNING

Do not exceed the safe flow rate. Do not increase flow through system by increasing pump size or horsepower.

Do not allow children to sit, play or interact with main drains or suction outlet.

Any and all broken or missing parts must be replaced prior to starting spa or pool pump. Never operate spa or 

pool without drain cover in place and properly affixed, death or serious injury can result.

It is imperative to securely attach the suction cover to the wall fittings (use only the original supplied screws 

or obtain original replacements). Do not over tighten the screws. Inspection of fasteners and observation for 

damaged/tampered with suction fittings is required.

810-0256-2017.0521

©2021 Waterway Plastics

• Use two or more suction fitting on each  
pump suction line. The suction fittings    
shall be separated by a minimum of 3 ft. 
(91.44 cm), or if any are located closer they 
shall be located on two different planes 

  (i.e., one on the bottom and one on the vertical wall, or one each on  
  two separate vertical wall).
•   In the event of one suction outlet being completely blocked, the    
  remaining suction outlets serving that system shall have a flow    
  rating capable of the full flow of the pump(s) for the specific suction  
 system.
•   Dual suction fittings shall not be located on seating areas or on the  
  backrest for such seating areas.
•   The maximum system flow rate shall not exceed the flow rating of  

  any listed (per ASME A112.19.8-2007) suction outlet cover installed.  
  In the event of one suction outlet being completely blocked, the    
  remaining suction outlets serving the system shall have a flow rating  
  capable of the full flow of the pump(s).
•   Never use a pool or spa if any suction outlet component is damaged,  
  broken, cracked, missing, or not securely attached.
•   Replace damaged, broken, cracked, missing, or not securely attached  
  suction outlet components immediately.
•   Two or more suction outlets per pump should be installed in  

 

  accordance with latest APSP Standards and CPSC guidelines, and    
  follow all National, State, and Local codes applicable.
•   Replace the suction within 7 years from the installation date.
•   Installation of a vacuum release system, which relieves entrapping  
  suction, is recommended.

TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

Summary of Contents for 640-213 V Series

Page 1: ... SUCTION OUTLET 640 213x V 810 0256 2017 0521 2021 Waterway Plastics 2200 East Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 www waterwayplastics com waterway waterwayplastics com Designed Engineered Manufactured in the USA ...

Page 2: ...anical entrapment This cover grate shall only be installed on the sump configuration authorized by these instructions SOFA configuration 640 213xV with certified flow rating 178 gpm floor 132 gpm wall USE ONLY GENUINE WATERWAY REPLACEMENT PARTS IMPORTANT SAFETY INSTRUCTIONS For Model Numbers 640 213xV 810 0256 2017 0521 2021 Waterway Plastics SOFA INSTRUCTIONS When installing and using this equipm...

Page 3: ...each operational day During installation ensure components and fastener receptacles are clean free of debris and obstructions Hand check cover grate for snugness to the sump frame wall fitting after installation SOFA installation components with crack chunks or pieces broken off stripped screw holes and or unusual discoloration should be replaced The mounting surface or interior surface of the poo...

Page 4: ...sing parts must be replaced prior to starting spa or pool pump Never operate spa or pool without drain cover in place and properly affixed death or serious injury can result It is imperative to securely attach the suction cover to the wall fittings use only the original supplied screws or obtain original replacements Do not over tighten the screws Inspection of fasteners and observation for damage...

Page 5: ...17 0521 2021 Waterway Plastics A PVC Pipe 2 B Minimum Sump Depth 0 C Minimum Ledge Depth 1 D Minimum LedgeWidth 1 2 E Minimum Pipe Offset 1 2 F Minimum Length Before Reduction 16 Pipe Orientation Vertical to pool surface 10 010 FINISH SURFACE OF THE POOL FINISH SURFACE OF THE POOL 642 3180 FLOW PATH LENGTH 4 ...

Page 6: ...spa you must contact a licensed pool builder or remodeler to install a second point of suction ULTRA RETRO SUCTION OUTLET INCLUDED COMPONENTS ULTRA RETRO SUCTION OUTLET IMPORTANT INFORMATION Your Ultra Retro includes five important components All components 1 4 below must be used for proper installation These components are as follows 1 Drain cover support plate 2 Drain cover 3 Three 10 x 7 8 secu...

Page 7: ... 2 642 3170V 10 Ultra Retro Suction Cover 4 819 0910 10 x 5 8 Self Threading Screw 5 819 0912 10 x 7 8 Self Threading Screw 6 819 0911 10 x 1 1 4 Self Threading Screw 7 819 0999 8 32 x 3 4 Screw 8 642 3180 Support Plate 9 642 3220B Spacer Bushing 10 821 0010 10 Plastic Anchor 810 0256 2017 0521 2021 Waterway Plastics ...

Page 8: ...CAUTION Failure to use the correct spacers may cause the pool cover support plate to be pulled from the pool or spa surface This replacement SOFA is only acceptable for use if the provided fasteners can be installed as intended by these instructions Verify proper installation by checking that the sump dimensions meet the required dimensions shown for values A through F as well as the required pipe...

Page 9: ...8 over the ring or sump Figure 5 The top of the outlet pipe should be recessed a minimum of 1 inch from the back of the plate Figure 6 5 Attach the drain cover support plate to the pool or spa surface with the appropriate screws fasteners and spacers as described in 3 above Figures 6 or 7 Once installed be sure that the drain cover support plate is firmly in place and cannot be pulled out of the p...

Page 10: ... plate of the Ultra Retro and the pool finish must be filled An underwater epoxy such as AB epoxy putty may be used or if the pool is empty then silicon glue may be used Allow for the drying time in both cases before suction is applied to the drain cover CAUTION the SOFA back plate CANNOT be attached to the wall using the adhesive s NOTE For fastener repair evaluation and replacement if any of the...

Page 11: ...way Plastics 2200 East Sturgis Road Oxnard CA 93030 Phone 805 981 0262 Fax 805 981 9403 www waterwayplastics com waterway waterwayplastics com Designed Engineered Manufactured in the USA 20 50 100 Flow Rate GPM 35 7 89 0 178 1 Total Head Loss Hg 0 18 1 02 4 26 Hg GPM 2 Connection measured 15 downstream of the 90 elbow that was directly attached to the sump in this case the fittings used to create ...

Reviews: