Error
6711
U
Reset HP
No, Yes
No
6740
S
Flow temp HC1 alarm
--, 10... 240 min
10 min
--
6741
S
Flow temp HC2 alarm
--, 10... 240 min
10 min
--
6745
S
DHW charging alarm
--, 1... 48 h
1 h
--
6746
S
Flow temp cooling 1 alarm
--, 10... 240 min
10 min
--
6800
S
History 1
Time, Date, Error code
6802
S
History 2
Time, Date, Error code
6804
S
History 3
Time, Date, Error code
6806
S
History 4
Time, Date, Error code
6808
S
History 5
Time, Date, Error code
6810
S
History 6
Time, Date, Error code
6812
S
History 7
Time, Date, Error code
6814
S
History 8
Time, Date, Error code
6816
S
History 9
Time, Date, Error code
6818
S
History 10
Time, Date, Error code
Service / Special operation
7070
S
HP interval
--, 1... 240
1 month
--
7071
S
HP time since maint
Reset ? (no, yes)
0 240
1 month
0
7072
S
Max starts compr1/hrs run
--, 0,1... 12
0,1
--
7073
S
Cur starts compr1/hrs run (since the 6 last weeks)
Reset ? (no, yes)
0 12
0
7076
S
Diff condens max/week
--, 1... 250
1
--
7077
S
Cur diff condens max/week
Reset ? (no, yes)
0 250
0
7078
S
Diff condens min/week
--, 1... 250
1
---
7079
S
Cur diff condens min/week
Reset ? (no, yes)
0 250
0
7090
S
DHW storage tank interval
--, 1... 240
1 month
---
7091
S
DHW stor tank since maint
Reset ? (no, yes)
0 240
0
7141
U
Emergency operation
Off, On
Off
Off : The heat pump does not use the backup electrical heating system or the boiler connection when a fault occurs (error 370)
On : The heat pump uses the backup electrical system or the boiler connection when a fault occurs (error 370).
In the "On" position, the energy costs can be onerous if the error is not eliminated.
7142
S
Emergency operating function type
Manual, Automatic
Manual
Manual : Emergency mode is not active when a fault occurs. (Emergency mode = OFF)
Automatic : Emergency mode is active when a fault occurs. (Emergency mode = ON)
In "Automatic" position, the energy cost can be onerous if the error is not detected and eliminated.
7150
I
Simulation outside temp
---, -50... 50 °C
0,5
--
7181
I
Phone no. responsibility 1
0 255
7183
I
Phone no. responsibility 2
0 255
Line
Function
Setting range
or display
Setting
increment
Basic
setting