background image

 

 

                                                                                                                                                   

 

                                                                                                                                         

21

Service Instructions / Instructional Videos

Available at www.watersoftinc.com

A. 

General Preliminary Instructions 

 

PERFORM BEFORE ALL SERVICING OPERATIONS

 

1. Turn off water supply to conditioner.

 

    -If the conditioner installation has a “three valve” bypass system, first open the valve in  the bypass line, then    

 

     close the valves at the conditioner inlet and outlet.

 

    -If the conditioner has an integral bypass valve, put it in the bypass position.

  

    -If there is only a shut off valve near the conditioner inlet, close it.

 

2. Remove cover and relieve water pressure in the conditioner by stepping the control into the backwash 

 

    position momentarily. Return the control to the service position.

 

3. Unplug electrical cord from outlet.

 

B. 

To Replace Powerhead

 

1. Remove the control valve cover and disconnect the power supply.

 

2. Disconnect the meter cable from circuit board and feed back through control (if existing meter is being re-used)

 

3. Remove lower back base screws and detach lower back base.

 

4. Remove screw and washer at drive yoke. Remove powerhead mounting screws. The entire powerhead 

 

    assembly will now lift off easily.

 

5. Put new powerhead on top of the valve. Be sure the drive pin on main gear engages slot in drive yoke (wide 

 

 

    side of drive yoke upright must face to the left away form the motor). 

 

6. Replace powerhead mounting screws. Replace screw and washer at drive yoke.

 

7. Reattach lower back base.

 

7. Reconnect meter signal, wire and power supply.

 

8. Reinstall cover.

C. 

To Replace Piston Assembly

 

1. Follow steps 

A1 - A3

 

2. Disconnect the meter signal wire from the circuit board.

 

3. Remove lower back base screws and detach lower back base.

 

4. Remove screw and washer at piston drive yoke. Remove powerhead mounting screws. The entire powerhead    

 

    assembly will now lift off easily.

 

5. Remove piston retaining plate screws.

 

6. Pull upward on end of piston yoke until assembly is out of valve.

 

7. Inspect the inside of the valve to make sure that there is no foreign matter that would interfere with the valve 

                 operation. 
 

8. Install new seals and spacers.

 

9. Take new piston assembly and push piston into valve by means of the end plug. Twist drive yoke carefully in a   

 

    clockwise direction to properly align it with drive gear. Reinstall piston retaining plate screws.

           10. Follow steps 

B5 - B9

D. 

To Replace Seals and Spacers

 

1. Follow steps 

A1 - A3

.

 

2. Disconnect the meter signal wire from the circuit board.

 

3. Remove screw and washer at piston drive yoke. Remove powerhead mounting screws. The entire powerhead    

     

    assembly will now lift off easily. Remove piston retaining plate screws. 

 

4. Pull upward on end of piston rod yoke until assembly is out of valve. Remove seals and spacers. (Note: Special  

 

    end spacer must be reused)

 

5. Lubricate new seals with silicone lubricant included in the seal and spacer kit. Make sure the special end  

 

    

    spacer is properly seated in the valve body. Install new seals and spacers individually, pressing around the  

 

    

    outer edge of each seal to make sure it is seated.  (When all seals and spacers are seated properly, you will    

  

    have a 1/4” of space between the top seal the the top of the valve body)

             6. Follow Steps 

C9 - C10

.

Summary of Contents for ISOBAR II

Page 1: ...Installation Operation Manual...

Page 2: ...ammingtheControlValve Page 11 Master Programming Mode Page 14 Control Valve Powerhead Assy ISO II ISO III Page 15 Valve Body Assembly ISO II Page 16 Bypass Assembly ISO II Page 17 Valve Body Assembly...

Page 3: ...art LT 150 Sealants Pipe dope and liquid thread sealers may contain a carrier that attacks some plastic materials It is recommended that Teflon tape be used to seal plastic Noryl threaded fittings Gen...

Page 4: ...g required for filter connection e g copper galvanized PVC plastic Note If household plumbing is galvanized and you intend to make the installation with copper or vice versa obtain di electric unions...

Page 5: ...istributor tube to prevent material from entering tube while filling C Place media funnel in hole on top of tank D Pour several gallons of water in the tank Fill tank about 1 3 full E Pour in the requ...

Page 6: ...out on housing Note When re installing the drain line flow control housing be sure you hear and feel the O Ring pop into place before inserting the clip 2 Install 1 2 I D drain line tubing not include...

Page 7: ...nections have been made turn main water supply back on and check for leaks 2 Ensure that the bypass valve is in the BYPASS position and then cycle the control valve to RAPID RINSE Once the rapid rinse...

Page 8: ...he default password the first time you connect to it the app will ask you to enter the password After entering it the first time you should not need to enter it again unless it changes 3 BTLE Valve de...

Page 9: ...me This sets the amount of days between backwash cycles Example For 2am just type 2 and press OK Advanced Settings NOTE Consult your dealer before making any changes We do not recommend changing Advan...

Page 10: ...uctions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer...

Page 11: ...eft digit Backwash will begin at the set Backwash Time A 0 setting will cancel this feature The Max Value for this item is 29 Example Backwash every 7 days A 07 Factory Setting Cancel setting A 00 To...

Page 12: ...inish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position and then res...

Page 13: ...it is moving towards The default time at which regeneration will occur is 12 00 a m The motor s run direction during a particular regeneration cycle step is indicated by the rotation direction of the...

Page 14: ...Times Centuri Steps 2 3 4 5 Example 3 20 The next 4 displays set the duration of time in minutes for each backwash cycle step The step number which is currently modifiable is indicated on the far lef...

Page 15: ...Power Supply 20001X125 1 7 Back Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Switch Spacer 20111X004 1 11 Slide Cover 20111X001 1 12 Motor Screw SC2 4 13 Screw SC9...

Page 16: ...arb 20017X235 1 8 Drain Retainer Clip 20017X214 1 9 Brine Valve Plug O Ring 20001X230 1 10 Centuri Air Intake Check Valve 20944C250 1 11 10 24 X 1 Hex Screw 20001X226 2 12 Injector Cover 20001X223 1 1...

Page 17: ...17 Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 1 2...

Page 18: ...18 Valve Body Drive Assy...

Page 19: ...ssy 20009X228 1 11 Brine Line Ferrule 20251X305 1 12 Plug 20009X005 1 13 10 24 X 1 Hex Screw 20001X226 2 14 3 8 Push Lock Plug 20009X010 1 15 Injector Cover 360 20009X001 1 16 Injector Seal 20001X224...

Page 20: ...283 2 1 Female Straight Slip Set optional 20017X288 3 1 NPT Elbow Set 20017X284 4 1 NPT Straight Set optional 20017X289 5a Elbow Vertical Adapter Blank optional 20017X295 5b Elbow Vertical Adapter 1 4...

Page 21: ...cover C To Replace Piston Assembly 1 Follow steps A1 A3 2 Disconnect the meter signal wire from the circuit board 3 Remove lower back base screws and detach lower back base 4 Remove screw and washer a...

Page 22: ...nd clean or replace 4 Remove white injector and clean or replace 5 Apply silicone lubricant to injector seal and replace cover and screws 6 Unscrew air intake nut Clean or replace duckbill assembly F...

Page 23: ...quently Increase number of minutes in air draw cycle Clean injection assembly and screen instructions on page 11 4 Loss of Water Pressure Scaling fouling of inlet pipe Clean or replace pipline Pretrea...

Page 24: ...cle power to clear the error code Manually cycle the powerhead through the regeneration cycle steps to verify that the motor can cycle properly while the powerhead is disconnected from the valve body...

Page 25: ...25 Warranty...

Page 26: ...26...

Page 27: ...27...

Page 28: ...28 710 Orange Street Ashland OH 44805 PH 419 289 1500 FAX 419 289 1515 www watersoftinc com 3 2018...

Reviews: