NOTICE
All piping, fittings and valves must be suitable for pres-
sures that are present in the low and high pressure
stages.
Pump Water Drains
The pump is provided with a 3/4 NPT water drain. The drain
should be fitted with piping, valve and routed to suitable
draining location.
Tachometer Connection
If Optional Control Panel was not furnished:
The pump includes a magnetic pick-up installed in the pump
pedestal which allows a tachometer to be connected. A 10
meter cable is included with the pump which mates with the
magnetic
pick-up
(Amphenol
connector
part
no.
MS3106A-10SL-4S).
Wire the cable to the tachometer. Note that the magnetic
pick-up produces four pulses per revolution of the pump
shaft.
If Optional Control Panel was furnished:
The tachometer is included in the control panel and the wir-
ing to the magnetic pick-up was completed at the factory.
Optional Items
F
−
1031, Section 3032
Page 9 of 13
Solenoid Valve for PIV (Priming Isolation Valve)
Pump Water Drain