F-1031, Section 3028
Page 6 of 37
Compressor Component Dimensions - Oil Sump
CXSeries Fire Pump
Refer to F1031, Section 3014,
CX Series Fire Pump Installation Instruc-
tions
. See Page 22 for wiring interface between compressor and pump shift
throttle ready panel.
Compressor
General Guidelines
•
Components must be bolted to brackets welded to the pump compartment
frame or bolted directly to the pump compartment frame.
•
Allow enough clearance for routine maintenance, including clearance for
checking oil, adding oil, adjusting pressure, changing filters, cleaning screens
or opening drain valves.
•
The sump (oil/air reservoir) can be mounted at the same level as the com-
pressor or below it. If the sump must be mounted above the compressor (12
inches maximum), contact Waterous for the correct check valve to prevent
compressor flooding.
•
The sump must be horizontal, level and in the proper orientation. Do not relo-
cate or extend the sight glass.
•
The oil sight glass must be visible after all the components are installed so
oil level can be monitored easily.
•
The heat exchanger must be installed horizontally with the drain at the lowest
point.
•
To prevent damage to hydraulic and air lines or accidentally disconnecting
them, run them along the support beams of the pump compartment whenever
possible, bundled with cable ties or other fasteners.
•
Wire, hoses or tubing that passes through metal, such as a compartment pan-
el, must have a protective bushing or shield around the edge of the hole to
protect against abrasion.
•
To make troubleshooting easier, use colored air hoses as supplied and
shown on the air schematic (see Page 32 for color coding - Do not paint air
hoses).
•
Labeling the lines is strongly recommended.
CAUTION
Do not damage the vehicle chassis (also called frame or undercarriage)
during installation. Check with the vehicle manufacturer to make sure the
planned weld and bolts are in acceptable areas.
NOTICE
Summary of Contents for Eclipse ES
Page 5: ...F 1031 Section 3028 Page 5 of 37 Installation Mounting Clearances Required for Maintenance ...
Page 7: ...F 1031 Section 3028 Page 7 of 37 ...
Page 8: ...F 1031 Section 3028 Page 8 of 37 ...
Page 10: ...F 1031 Section 3028 Page 10 of 37 Oil Sump and Oil Temperature Sensor ...
Page 11: ...F 1031 Section 3028 Page 11 of 37 Air Oil Separator ...
Page 15: ...F 1031 Section 3028 Page 15 of 37 Compressor Air Connections ...
Page 16: ...F 1031 Section 3028 Page 16 of 37 Air Clutch Connection ...
Page 18: ...F 1031 Section 3028 Page 18 of 37 Water Drains ...
Page 19: ...F 1031 Section 3028 Page 19 of 37 Lubrication ...
Page 20: ...F 1031 Section 3028 Page 20 of 37 Electrical Wiring ...
Page 21: ...F 1031 Section 3028 Page 21 of 37 Power to Compressor Relay Panel Air Clu ...
Page 22: ...F 1031 Section 3028 Page 22 of 37 ...
Page 25: ...F 1031 Section 3028 Page 25 of 37 ...
Page 26: ...F 1031 Section 3028 Page 26 of 37 ...
Page 27: ...F 1031 Section 3028 Page 27 of 37 ...
Page 28: ...F 1031 Section 3028 Page 28 of 37 Oil Temperature ...
Page 32: ...F 1031 Section 3028 Page 32 of 37 Calibration ...
Page 34: ...F 1031 Section 3028 Page 34 of 37 Control Air Circuit Component Locations ...