GUARANTEE OF CORRECT INSTALLATION
NOTE TO CUSTOMER
Your Watermill Shower Pump will only work properly if it has been installed correctly. Ask your
installer to complete the following check list, ensuring it is signed and dated.
NOTE TO INSTALLER
While you are installing this shower pump tick the following “important instructions” to confirm to
both yourself and your customer this shower pump has been correctly installed.
If you need assistance please contact Watermill on the Service Helpline 01883 730339.
The shower pump must be installed in line with current water regulations and I.E.E. Regulations.
When the installation is completed please sign and date the Guarantee of Correct Installation and
then pass to customer to keep.
IMPORTANT INSTRUCTIONS
1.
Do not connect shower pump to water mains pressure. The shower pump
cannot
be used with combination boilers.
2.
The pump should have a supply head of at least 2 metres/6 ft. That is, the level
of the water in the tank must be this distance above the pump.
3.
a) Do not use
any
jointing compounds: these compounds will cause seals to leak.
b) If soldering pipe joints do
NOT
allow
ANY
solder flux to come in contact
with plastic parts of the shower pump. The plastic will be corroded and will
cause serious leaks.
4.
Flexible hoses must be used to connect the pump – do not connect any
pipework directly to the pump.
5.
Complete all pipework before making electrical connections.
6.
Do not run pump dry – purge with water thoroughly for 5 minutes before
running pump.
7.
Maximum hot water temperature must not exceed 60˚C (130˚F). The hot
water supply to the shower pump must
NOT
be connected to the hot water
cylinder expansion pipe.
8.
Please ensure that the installer has explained the correct operation of
the shower pump.
Signed:
Date:
Company:
If the shower pump installation does not conform to these instructions, the shower pump
guarantee may be invalidated and the cost of any “on site” visits by the Watermill Service
Department will be charged for.
6
Summary of Contents for PC25DLV
Page 9: ...7...