Watermill PC25DLV Installation Instructions Manual Download Page 5

5. COLD WATER SUPPLY

DO NOT USE ANY JOINTING COMPOUNDS OR TAPES

Watermill pumps are supplied complete with matching flexible hoses. These hoses must be
used to ensure strain and vibration free, watertight connections.
NOTE:  Do not connect metal (Brass/Iron) fittings directly onto pump inlets/outlets. The
threads are 3/4” BSP parallel and are designed for mating only with the flexible hose
connections, nuts and filters/washers supplied. 

DO NOT USE PTFE TAPE.

For ease of future servicing/filter cleaning, 22mm gate valves are recommended.
The filters supplied should be inserted in the pump 

inlets

only – with the wire dome

towards the pump.

Position pump level on floor, with outlets (flowswitches) vertical. For correct operation

the 

flowswitches must be vertical.

Position supply pipes and shower hoses accurately so that the pump is not under any

mechanical strain, such as supporting weight of
pipes. Ensure correct alignment to prevent cross
threading and to prevent seals and filters from
leaking.

Line up pipework and fit hoses to pipes

before attaching connectors to pump.

Do not bend hoses as this will cause

restriction of flow.

The plastic nuts should be finger tight plus

1/2 turn. The nuts should be re-tightened after
hot water has been pumped for the first time.

Ensure filters are fitted to the inlets and

washers to outlets.

6. CONNECTING PUMP

4. HOT WATER CYLINDER CONNECTIONS

DO NOT USE ANY JOINTING COMPOUNDS.

The use of a Surrey Flange; see Fig. 1 is recommended to ensure a free flowing supply of “air

free” hot water. Ensure that:

• The controlled hot water temperature is no greater than 60°C.
• Maximise size of pipework to the pump.

Note: All plumbing work should conform to Water Supply (Water Fittings) Regulations
1999.

The hot water feed may be taken directly from the top of the hot water cylinder – but
entrapped air may cause problems.

22mm copper pipe must be used to ensure an adequate flow to the pump. An isolating

gate valve or full bore lever valve is recommended to facilitate pump servicing.

The negative head kit provides for a pneumatic push button and air switch. This enables the
pump to be started by pressing a push button located in the shower area.

DO NOT CONNECT DIRECTLY TO WATER MAINS
DO NOT USE ANY JOINTING COMPOUNDS

The cold water supply to the pump should be connected only from the cold water cistern (do
not connect to the central heating header tank!) see Fig. 1. The tank connector should be
positioned at least 25mm (1”) lower than the cold water feed to the hot water cylinder; see
Fig. 1.

An isolating gate valve is recommended to facilitate pump servicing, also 22mm copper

pipe is recommended for connection on the cold water inlet.

3

Summary of Contents for PC25DLV

Page 1: ...INSTALLATION INSTRUCTIONS LOW VOLTAGE SHOWER PUMPS Models PC25DLV PC50DLV PC55SLV PC70DLV ANHPC60DLV CUSTOMER SERVICE HELPLINE 01883 730339 Performance Shower Products...

Page 2: ...ollow the appropriate sections PAGE 1 GENERAL 1 2 IMPORTANT INSTRUCTIONS 1 3 POSITIONING PUMP 1 4 HOT WATER CYLINDER CONNECTIONS 3 5 COLD WATER SUPPLY 3 6 CONNECTING PUMP 3 7 ELECTRICAL CONNECTIONS 4...

Page 3: ...2 metres If the pump is to be installed in the loft the height from the top of the water in the cold water storage tank must be at least 2 metres above the inlet to the pump 4 Do not use any jointing...

Page 4: ...n the cold water storage cistern and the outlet of the shower handset of 250mm 10 See Fig 1 Negative Head If the water level of the cold water storage cistern is below the level of the shower outlet t...

Page 5: ...has been pumped for the first time Ensure filters are fitted to the inlets and washers to outlets 6 CONNECTING PUMP 4 HOT WATER CYLINDER CONNECTIONS DO NOT USE ANY JOINTING COMPOUNDS The use of a Sur...

Page 6: ...should have supplementary earth bonding Where the earth continuity has been broken by flexible pipes the pump discharge and suction pipework should be connected with earthing clamps to BS951 and 4mm...

Page 7: ...ter temperature to 60 C 2 Ensure adequate feed to the pump There should be at least a 2 metre lead measured from cold storage water level to input of pump and all pump supply pipes should be with 22mm...

Page 8: ...ly head of at least 2 metres 6 ft That is the level of the water in the tank must be this distance above the pump 3 a Do not use any jointing compounds these compounds will cause seals to leak b If so...

Page 9: ...7...

Page 10: ...3m 17m 20m Max Working Pressure 3 bar 3 bar 3 bar 3 bar Approx Starting Flow Rate 0 5lpm 0 5lpm 0 5lpm 0 5lpm DIMENSIONS Length mm 275 275 225 285 Width mm 120 120 120 120 Height mm 185 185 185 185 NO...

Page 11: ...s of purchase accompanied by a copy of the original invoice proof of purchase We will acknowledge receipt of the guarantee registration card within ten days It is this guarantee acknowledgement that a...

Page 12: ...ot suitable for the application It helps us to help you if we can obtain details of the application It is also very useful to have digital photographs of the installation e mailed to service watermill...

Reviews: