1. Introduction: 
 

The 

Rainsaver  MK4E

  is  an  Automatic  Rainwater  /  Mains  Water  Changeover  Device  designed  to 

provide automatic mains back up for Pressure Pump supply systems.  
 
The 

Bianco  Rainsaver  MK4E

  is  designed  to  be  installed  in  conjunction  with  a  DAB  or  Bianco 

surface mounted or submersible Pressure Pump supply system that is fitted with a 

FLOAT SWITCH 

(except  for  the  DAB  DIVERTRON)  as  well  as  an  independent 

PRESSURE  AND  FLOW 

CONTROLLER

 with 

LOSS OF PRIME PROTECTION 

and

 AUTOMATIC RE-START. 

 
WARNING! 

The 

Rainsaver MK4E

 

is NOT A PUMP CONTROLLER! 

 

 

2. General Specifications: 

 
Controls pumps to a maximum 1.5 hp, 1.1 kW 240V. 
Maximum water temperature (mains + pump): 40

C. 

Maximum recommended continuous pump flow: 100 litres per minute. 
Maximum recommended pump pressure: 800 kPa. 
Maximum recommended mains inlet pressure: 800 kPa. 

 
3. Operation: 

 
The 

RainsaverMK4E 

supplies clean rainwater from a rainwater tank via an automatic pressure 

system pump to toilets, laundry and garden taps in a household. 
 
Mains water is also connected to the

 RainsaverMK4E 

as an automatic back up should rain water level be 

too low, or if there is a power or pump* failure). 
*Should there be a pump failure, mains back up is achieved by turning the 

RainsaverMK4E 

off at the 

power point. 
 
The low voltage float switch supplied prevents the pump from running dry and allows automatic switch 
over to mains supply should the rain water level in the tank be too low. 

 
4. Installation: 

 

4.1 Pump Float Switch installation. 
 

The 10m, 12V DC low voltage float switch supplied, prevents the pump from running dry and allows 
automatic  switch  over  to mains  supply.  It  is  supplied  complete  with a  counterweight  and  water  tank 
mounting plate, and is designed to enter the rainwater tank from the roof of the rainwater tank. 
 
Choose a location on the roof of the rainwater tank to cut the 85mm hole required. The centre of the 
hole  should  be  at  least  200  mm  away  from  the  side  of  the  tank  as  well  as  being  200mm  away 
horizontally  from  tank  rainwater  entry  and  rain  water  tank  outlet.  Any  shavings  should  be  removed 
with a vacuum cleaner. 
 
Uncoil and lay out the float switch cable. Move the counterweight so that it is 

200 mm from the float 

switch. 

Tighten the cable gland on the counterweight to lock it in position. 

 
Position  the  float  switch  cable  in  the  water  tank  mounting  plate  so  that  the  distance  between  the 
mounting  plate  and  the  end  of  the  float  switch  is 

100  mm  less  than  the  depth  of  the  tank  when 

measured from the float switch access hole

, and tighten the cable gland and conclamp. 

 
Submersible pumps supplied with the 

RainsaverMK4E

 may have a pump mounted float switch which 

needs to be cable tied so that it is always in the vertical position. 
 
 
 

Summary of Contents for rainsaver Bianco RainsaverMK4E

Page 1: ...Bianco RainsaverMK4E Installation and Operating Instructions Bianco RainsaverMK4E is WaterMark Level 1 approved to ATS5200 477 2006 Certificate No 23022 and incorporates internal dual check valve back flow prevention for the mains water ...

Page 2: ...turning the RainsaverMK4E off at the power point The low voltage float switch supplied prevents the pump from running dry and allows automatic switch over to mains supply should the rain water level in the tank be too low 4 Installation 4 1 Pump Float Switch installation The 10m 12V DC low voltage float switch supplied prevents the pump from running dry and allows automatic switch over to mains su...

Page 3: ...ge pressure should be 65 of pump maximum pressure Wall Mounting Instructions To reverse the mounting direction so that Mains inlet will be on the left side and House outlet on the right follow the first steps of Pump Mounting Instructions below to remove and reverse the mounting bracket Then continue Remove the RainsaverMK4E lid by unscrewing the 4 Phillips head screws Hold the RainsaverMK4E in th...

Page 4: ...e housing This will stop insects creating a nest inside the Rainsaver Unit Replace the lower union nut and pipe being sure that internal components are in place and that the o ring is properly seated Leave the lower union nut slightly loose to allow fitting and alignment to pump Attach the BSPT male pipe fitting to the pump outlet either directly or using plastic threaded pipe fittings as required...

Page 5: ...n x F I elbow fitting to connect between copper tubing and BSPT threaded pipe fitting at the MAINS inlet PUMP INLET if unit is wall mounted and HOUSE outlets Use standard BSP female threaded fittings to connect to BSPT threaded pipe fitting when connecting other types of piping DO NOT REMOVE THE UNION NUT AND BSPT PIPE FITTING AND ATTEMPT TO CONNECT PIPE WORK DIRECTLY TO THE BODY OF THE UNIT DO NO...

Page 6: ...urer s instructions regarding pressurization of your pressure tank 4 7 Pressure Tank Pre charge To ensure optimum performance and system life the Pressure Tank pre charge needs to be set by filling the pressure tank with air through the air valve so that the air pressure is 65 of the pump maximum pressure Pre charge the pressure tank before it is installed by using an air pump or using the local s...

Page 7: ...mains regularly or at least once a month by turning the power off to the RainsaverMK4E 7 Trouble shooting Consult the manuals supplied with the water pump and its controller if fitted in addition to the following guide 1 Mains flow is not available or low when Pump is switched off or not operating a Isolation valve if fitted is not open b Debris has jammed the mains inlet check valve closed c Exte...

Page 8: ...tands high inlets floating suction hose kits assist in the pumping cleaner water that is found at higher levels in the rainwater tank See pump installation accessories on page 13 9 Water Tanks Water borne algae and roof litter can accumulate at the bottom of your rainwater tank that can be sucked up by your pump To reduce filter blockages we recommend that suction outlets on rainwater tanks be 100...

Page 9: ...INSTRS110110 rev 6 01 03 15 Page 9 Installation Dimensions ...

Page 10: ...INSTRS110110 rev 6 01 03 15 Page 10 Typical Installations DAB or BIANCO surface mounted pumps RAINSAVER MK4E RAINSAVER MK4E ...

Page 11: ...INSTRS110110 rev 6 01 03 15 Page 11 TESLA DIVERxxxMPCX Submersible Pump RAINSAVER MK4E RAINSAVER MK4E ...

Page 12: ...INSTRS110110 rev 6 01 03 15 Page 12 BIANCO JH8003PMPCX or B42A Submersible Pumps RAINSAVER MK4E RAINSAVER MK4E ...

Page 13: ...INSTRS110110 rev 6 01 03 15 Page 13 DAB DIVERTRON1200 Submersible Pump RAINSAVER MK4E RAINSAVER MK4E ...

Page 14: ...p Cover protects pump from the elements Pump stand for submersible pumps lifts pump up to pump cleaner water DAB Divertron X conversion kit allows pumping from higher level and connection to floating suction kits to pump cleaner water higher in the tank ...

Page 15: ... conversion kit allows pumping from higher level and connection to floating suction kits to pump cleaner water Floating suction hose kits allow pumping from cleaner water higher in the tank Float switch for bladder tank Piggy back float switch option for Divertron ...

Page 16: ...INSTRS110110 rev 6 01 03 15 Page 16 ...