Use Guidelines
Use Guidelines
•
Use for mains water supply.
•
Minimum operating pressure 200 kPa.
•
Maximum operating pressure 500 kPa.
•
Do not allow exposure to temperatures below 0 °C, protect from freezing.
•
Maximum operating temperature 38 °C.
•
Nominal flow rate 2 Lpm.
•
System must be installed according to local plumbing codes on the cold water line only.
•
This system requires regular replacement of the filter cartridge to maintain proper
operation. Varying chlorine, sediment, or organic substance levels may affect
replacement frequency.
•
Be sure to change the filter cartridge every 6 - 12 months or whenever you detect a
change in taste, odour, or decrease in flow.
Caution:
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before the chiller.
Cold Thermostat
Compressor
Fan
Fuse
Fig. 4 - Electrical Diagram