STEPS 
1. Unscrew the tail from 
the body. 

 

2. Unscrew the nut 
and remove the 
washer and the 
bottom gasket 
from the body. 

 

3. Place the rest of the 
drain into the sink from 
the top. If the cap has a 
Watermark logo on it 
then make sure to align 
it to the desired 
orientation. 

 

4. Place the 
bottom gasket on 
top of the nylon 
washer, then place 
the nylon washer 
on top of the nut, 
finally screw the 
nut back onto the 
body. Do not over 
tighten the nut. 

 

5. Apply Teflon tape to the thread on the tail and 
screw the tail back into the body. 

6. Connect the drain to the trap and check for 
leaks. 

 

 

IMPORTANT INSTALLATION INFORMATION 

 

USE TEFLON TAPE OR PIPE SEALANT FOR THREADED CONNECTIONS 

 

DO NOT 

USE PLUMBER’S PUTTY ON ANY OF THE BRASS COMPONENTS

 

This will cause the finish to tarnish. A non-corrosive Alkoxy Silicone is recommended. 

 

DRAINS ARE ONLY UNDER WARRANTY FOR MECHANICAL FAILURE, NOT FOR FINISH DEFECTS 

 

 

For technical support, please call 718-257-2800 

 