IMPORTANT SAFETY INSTRUCTIONS
WATERMAID ELECTROLYTIC CHLORINATOR MODEL WM10LED CHLORINE
GENERATING DEVICE
DOMESTIC
FOR RESIDENTIAL POOLS AND SPAS
REGISTRATION NUMBER 28114
PEST CONTROL PRODUCTS ACT
When installing and using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNERS MANUAL AND ON THE LABEL BEFORE USING
a)
To reduce the risk of electric shock, the ground wire of this device must be
connected to the grounding means provided in the electricity supply service panel with a
continuous copper wire equivalent to the circuit conductors supplying the equipment.
b)
WARNING: KEEP OUT OF THE REACH OF CHILDREN
c)
WARNING: Risk of electric shock. Connect only to a grounding type receptacle
protected by a ground fault circuit-interrupter (GFCI). Contact a qualified electrician if you
cannot verify that the receptacle is protected by a GFCI.
d)
Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
e)
WARNING: To reduce the risk of electric shock, replace damaged cord
immediately. To avoid hazard, the supply cord, if damaged, must be replaced by the
manufacturer or its service agent or a similarly qualified person.
f)
WARNING: To reduce the risk of electric shock, do not use an extension cord to
connect unit to electricity supply; provide a properly located outlet.
g)
CAUTION: to prevent electric shock, switch OFF the power at the electrical
power outlet before dislodging the WATERMAID Power Supply. Do NOT remove the
cover, as there are no user serviceable parts inside. Refer to a qualified service
technician for repair.
h)
Maintain water chemistry in accordance with manufacturer's instructions.
IMPORTANT
* The WM10 chlorinator is designed to run at a maximum salt level of 6000 ppm.
* This unit MUST be installed AT LEAST 3m (10 feet) from the inside wall of the pool.
* The WATERMAID QT SERIES Cells must be installed with a gas-trap to prevent any gases
getting back into the filter.
* The WATERMAID Cell must be installed so that ALL the water from the filter passes through the
WATERMAID Cell before any diversions or breakouts.
* Ensure that the WATERMAID Power Supply is OFF or in standby mode [refer to section 4] when
adding salt to the water or water flow is restricted (e.g. backwashing the filter, blocked skimmers,
etc) [refer to section 6(vi)].
* It is recommended that between 5Kg and 25Kg per year of Magnesium [Magnesium Sulphate
("Epsom Salts") or Magnesium Chloride] be added to the pool water.
* Do NOT add any products containing Calcium to the pool water.
* Use with a pump rated at 1 HP or above.
* Do NOT strike the Cell with any kind of instruments.
WARNING: Improper installation or operating the Watermaid electrolytic chlorinator
model WM10LED without water flow through the cell can cause a buildup of flammable
gases, which can result in FIRE OR EXPLOSION
Registrant:
Canadian Agent:
W
ATERMAID PTY LTD W
atermaid
of
Canada
Inc.
24
Tepko Road,
16
Blyth
St.
Terry Hills, NSW 2084
Richmond Hill, ON
Australia
Canada. L4E-2Y1
1-877-987-6243
29-OCT-2010
2010-3637