background image

‘Watermaid’ systems from Australia - 

Sole importers:

 

Watermaid Europe S.L.

 

Company registration No: 806340809 - CIF No: B30826044

 

 

Watermaid Europe S.L - Registered Address:. 

Apt. 1285, Calle Azaleas 650, Urb. Camposol,  Mazarrón 30875 Murcia. 

Telephone: (00 34)  636 698 501 – 646 705 088

 

 
 

 

THE WATERMAID WM10 FRONT CONTROL PANEL

 

 

The 

WATERMAID

 WM10 Power Pack has a control panel that consists of an LED, chlorine production 

readout indicating the percentage (%) of chlorine production being produced by the WATERMAID cell. 
The  Chlorine  Production  rate  of  the  WATERMAID  Unit  can  be  set  at  a  desired  level  by  using  the 

-

 or 

+

 buttons on the front Control Panel. 

 
The  %  figures  shown  on  the  front  of  the  Watermaid  WM10  Power  Pack  correspond  to  the  following 
chlorine production values below. 
 

% Reading

 

Amps

 

Grams / Hour

 

Liquid Chlorine Equivalent / 10 Hrs 

(12.5% Available Chlorine) 

 

 

 

 

25%

 

7.5 A

 

~ 7.5 gr/hr

 

600 Millilitres / 0.16 Gallons

 

50%

 

15 A

 

~ 15 gr/hr

 

1.2 Litres / 0.32 Gallons

 

75%

 

22.5 A

 

~ 22.5 gr/hr

 

1.8 Litres / 0.48 Gallons

 

100%

 

30 A

 

~ 30 gr/hr

 

2.4 Litres / 0.63 Gallons

 

 
There are Six influencing factors that determine the chlorine output that is produced by the cell. 
 

1.

 

THE CONTROL PANEL SETTING -- 

This is the level that is set by the user by depressing the 

- or + buttons. The actual reading that is obtained will also be influenced by the five other factors 
listed below. 

2.

 

THE REQUIRED LEVEL SETTING WILL DEPEND – 

upon the size of the pool, how many 

people are using the pool, how well the pH is controlled and filtration running cycle.

 

3.

 

SALT  LEVEL  -- 

The  salt  level  in  the  water,  determines  how  conductive  the  water  is  and  how 

much  current  (Amps)  the  cell  is  able  to  draw  from  the  Power  Pack,  proportional  to  the  LED 
readout on the front panel of the WATERMAID Power Pack. 
 
A recommended Salt Level of 5000 PPM (parts per million) will result in a EZ300 Cell or QT300 
Cell drawing approximately 30Amps or 100% reading on the indicator LED's. 
A salt level below this range will result in the LED readout to drop to below 100% and therefore 
less chlorine being produced. 