Page 1: ...Limited Second Floor Suite 4 Beacon Court Sandyford Co Dublin Ireland Tel 353 0 1293 1960 Fax 353 0 1293 1052 For Technical Support Email support waterlogicsupport zendesk com WLI UK LTD Global Headquarters Grenfell Road Maidenhead Berkshire SL6 1HN United Kingdom ...

Page 2: ...use by these qualified individuals Waterlogic encourages users to learn about products however we believe that product knowledge and service is best obtained by consulting Waterlogic or an Authorized Waterlogic Dealer Waterlogic Water Purification Systems should be combined with selected water treatment components to create a system specifically tailored for each application by trained and qualifi...

Page 3: ...CONTENTS Safety Alert Symbols 4 Safety Precautions 4 Features and Benefits 6 Firewall Purification System 7 Certifications 8 Model Designations and General Specifications 9 Electrical and Shipping Specifications 10 Operating Instructions 11 User Interface 12 Disposal 12 ...

Page 4: ...ct against electrical shock and exposure to UVradiation DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly earthed outlet Unit should be protected by ground fault circuit interrupter GFCI or residual current device RCD having a rated residual operating current not exceeding 30mA Use only Waterlogic supplied power cord Never use extension cords or power strips to connect unit Do not...

Page 5: ...proper management and transportation of the machine to avoid damaging the refrigerant fluid and causing a dangerous leak Discarded appliance should be isolated from fire sources and cannot be burned Please transfer the appliance to qualified professional recycling companies for processing to avoid damages to the environment or other hazards WARNING Keep ventilation openings in the appliance enclos...

Page 6: ...ll indoors and keep unit away from humidity levels above 65 Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around the unit Minimum clearance around all surfaces of the machine is 50mm Installs where the ambient temperature exceeds 25 C require a minimum of ...

Page 7: ...bits the growth of microorganisms providing additional surface protection Large Dispense Area with Recessed Sanitary Faucet Increased dispense height to accommodate large vessels Intuitive recessed dispense area with smooth cleanable surfaces Removable BioCote Drip Tray Drip tray features a two piece design for easy cleaning BioCote protection and an optional drain port Customizable Programming Se...

Page 8: ...E FIREWALL PURIFICATION SYSTEM Our breakthrough Firewall technology delivers 99 9999 bacteria free water right at the point of dispense Firewall delivers the safest water possible through a sanitary faucet right to your cup Certified to the Highest Standards ...

Page 9: ...is certified by IAPMO R T according to NSF ANSI 42 NSF ANSI 53 NSF ANSI 55 Class A NSF ANSI P231 US EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers for the reduction of the contaminants on the Performance Data Sheet NSF ANSI 372 for lead free compliance See the performance data sheet for specific reduction claims System claims vary depending on filters used within the s...

Page 10: ...ter Output 95 C 203 F Factory Set Point Output Flow 1 6Lpm Firewall Purification Rating Input Connections Quick Connect Bulkhead for Potable Water Recommended Water Feed 2 7 3 5 Bar 40 51 psi Always Use Pressure Regulator 2 LPM Maximum Flow Flow restrictor may be required Maximum Service Pressure 4 Bar 60 psi Always Use Pressure Regulator to Prevent Damage Feed Water Temperature 32 C 90 F Maximum ...

Page 11: ...r 100 W 1 2 A Controls 25 W 0 1 A Firewall UV System 13 W 0 2 A Pump Sparkling 12 W 0 1 A WL3FW TOTAL 950 W 5 6 A WL3 FW SHIPPING SPECIFICATIONS ITEM WL3 FW FS Tower Width Depth Height Box is 470 mm x 445 mm x 1245 mm 18 5 x 17 5 x 49 FS Tower Weight dry 29 5 kg 65 pounds Mini Table Top Width Depth Height Box is 470 mm x 521 mm x 585 mm 18 5 x 20 5 x 23 Mini Table Top Weight dry 25 kg 55 pounds ...

Page 12: ...s dispense limit TO DISPENSE SPARKLING WATER Select Sparkling dispense icon lower until it lights Hold until desired amount is dispensed Release to stop dispense There will be a 2 second initial delay as Firewall purifies sparkling water and sanitizes the faucet Sparkling will only dispense if Firewall is active to guarantee safest possible water Sparkling icon and Firewall Purification Light are ...

Page 13: ...timicrobial Surface Protection WL3FW features a modern look with advanced touch action dispensing equipped with back lights to improve user experience Intelligent dispensing limits continuous dispense to 1 minute as added safeguard Large 220mm opening to allow for sports bottle fill High Capacity 300 ml removable drip tray featuring BioCote antimicrobial surface protection End of Life DISPOSAL At ...