background image

WL3 FW 

User Manual

 

Page 4 - Revision:  EU 17-09-2020

 

 

 

SAFETY ALERT SYMBOLS

 

Read and follow all safety information carefully. The signal words used in this manual are selected as 
shown below and based on an assessment of the degree of potential injury or damage (severe or minor) 
and the occurrence of injury (definitely occurs or has the potential to occur) when the warning is 
ignored:

 

 

 

DANGER!  

Indicates a situation which, when not avoided, results in death or severe injury.

 

 

WARNING! 

Indicates a situation which, when not avoided, has the potential to result in death 

or severe injury; and/or severe property damage.

 

 

CAUTION! 

Indicates a situation which, when not avoided, results or has the potential to result 

in minor injury; and/or minor property damage.

 

SAFETY PRECAUTIONS

 

 

Basic safety precautions should be followed, including the following:

 

Ensure all local, state, and federal laws and codes including health and safety guidelines are met when 
installing 

Waterlogic 

Equipment. Only qualified service technicians should attempt installation and 

service of 

Waterlogic 

Equipment.  Always read the entire operating instructions before using the 

appliance and save these instructions for future use.

 

 

DANGER! 

This product can cause death or severe injury if incorrectly operated, installed or 

maintained. 

The installation, maintenance, sanitizing and any repair must be performed by qualified 

persons trained by Waterlogic International or their approved distributors only. Do not remove any 
panel or cover to protect against electrical shock and exposure to UV radiation.

 

 

DANGER! 

ELECTRICAL SHOCK HAZARD

Always use a dedicated and properly earthed outlet. Unit 

should be protected by ground-fault circuit interrupter (GFCI) or residual current device (RCD) having a 
rated residual operating current not exceeding 30mA. Use only Waterlogic supplied power cord. Never 
use extension cords or power strips to connect unit. Do not use if the power supply cord is damaged.

 

Always unplug from power supply prior to servicing. 

 

 

WARNING! 

AUTHORIZED USE ONLY. 

This appliance is to be used for its intended purpose as 

described in this manual, and untrained individuals who use this manual assume the risk of any resulting 
property damage or personal injury. This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or instruction concerning use of the appliance in a safe 
way and understand the hazards involved. Children shall not play with the appliance.  
Cleaning and user maintenance shall not be made by children without supervision. 
This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety.  
Children should be supervised to ensure that they do not play with the appliance. 

 

WARNING! 

SUPERVISE CHILDREN. 

Keep appliance and cord out of reach of children under the age of 

8years.  Children under the age of 8 years must not use or play with the appliance. 

 

 

Summary of Contents for WL3FW

Page 1: ...Limited Second Floor Suite 4 Beacon Court Sandyford Co Dublin Ireland Tel 353 0 1293 1960 Fax 353 0 1293 1052 For Technical Support Email support waterlogicsupport zendesk com WLI UK LTD Global Headquarters Grenfell Road Maidenhead Berkshire SL6 1HN United Kingdom ...

Page 2: ...use by these qualified individuals Waterlogic encourages users to learn about products however we believe that product knowledge and service is best obtained by consulting Waterlogic or an Authorized Waterlogic Dealer Waterlogic Water Purification Systems should be combined with selected water treatment components to create a system specifically tailored for each application by trained and qualifi...

Page 3: ...CONTENTS Safety Alert Symbols 4 Safety Precautions 4 Features and Benefits 6 Firewall Purification System 7 Certifications 8 Model Designations and General Specifications 9 Electrical and Shipping Specifications 10 Operating Instructions 11 User Interface 12 Disposal 12 ...

Page 4: ...ct against electrical shock and exposure to UVradiation DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly earthed outlet Unit should be protected by ground fault circuit interrupter GFCI or residual current device RCD having a rated residual operating current not exceeding 30mA Use only Waterlogic supplied power cord Never use extension cords or power strips to connect unit Do not...

Page 5: ...proper management and transportation of the machine to avoid damaging the refrigerant fluid and causing a dangerous leak Discarded appliance should be isolated from fire sources and cannot be burned Please transfer the appliance to qualified professional recycling companies for processing to avoid damages to the environment or other hazards WARNING Keep ventilation openings in the appliance enclos...

Page 6: ...ll indoors and keep unit away from humidity levels above 65 Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around the unit Minimum clearance around all surfaces of the machine is 50mm Installs where the ambient temperature exceeds 25 C require a minimum of ...

Page 7: ...bits the growth of microorganisms providing additional surface protection Large Dispense Area with Recessed Sanitary Faucet Increased dispense height to accommodate large vessels Intuitive recessed dispense area with smooth cleanable surfaces Removable BioCote Drip Tray Drip tray features a two piece design for easy cleaning BioCote protection and an optional drain port Customizable Programming Se...

Page 8: ...E FIREWALL PURIFICATION SYSTEM Our breakthrough Firewall technology delivers 99 9999 bacteria free water right at the point of dispense Firewall delivers the safest water possible through a sanitary faucet right to your cup Certified to the Highest Standards ...

Page 9: ...is certified by IAPMO R T according to NSF ANSI 42 NSF ANSI 53 NSF ANSI 55 Class A NSF ANSI P231 US EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers for the reduction of the contaminants on the Performance Data Sheet NSF ANSI 372 for lead free compliance See the performance data sheet for specific reduction claims System claims vary depending on filters used within the s...

Page 10: ...ter Output 95 C 203 F Factory Set Point Output Flow 1 6Lpm Firewall Purification Rating Input Connections Quick Connect Bulkhead for Potable Water Recommended Water Feed 2 7 3 5 Bar 40 51 psi Always Use Pressure Regulator 2 LPM Maximum Flow Flow restrictor may be required Maximum Service Pressure 4 Bar 60 psi Always Use Pressure Regulator to Prevent Damage Feed Water Temperature 32 C 90 F Maximum ...

Page 11: ...r 100 W 1 2 A Controls 25 W 0 1 A Firewall UV System 13 W 0 2 A Pump Sparkling 12 W 0 1 A WL3FW TOTAL 950 W 5 6 A WL3 FW SHIPPING SPECIFICATIONS ITEM WL3 FW FS Tower Width Depth Height Box is 470 mm x 445 mm x 1245 mm 18 5 x 17 5 x 49 FS Tower Weight dry 29 5 kg 65 pounds Mini Table Top Width Depth Height Box is 470 mm x 521 mm x 585 mm 18 5 x 20 5 x 23 Mini Table Top Weight dry 25 kg 55 pounds ...

Page 12: ...s dispense limit TO DISPENSE SPARKLING WATER Select Sparkling dispense icon lower until it lights Hold until desired amount is dispensed Release to stop dispense There will be a 2 second initial delay as Firewall purifies sparkling water and sanitizes the faucet Sparkling will only dispense if Firewall is active to guarantee safest possible water Sparkling icon and Firewall Purification Light are ...

Page 13: ...timicrobial Surface Protection WL3FW features a modern look with advanced touch action dispensing equipped with back lights to improve user experience Intelligent dispensing limits continuous dispense to 1 minute as added safeguard Large 220mm opening to allow for sports bottle fill High Capacity 300 ml removable drip tray featuring BioCote antimicrobial surface protection End of Life DISPOSAL At ...