WL200
Manual
Page 38 ‐ Revision: 4‐29‐2019
1.
Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.
Waterlogic
requires the use of a water pressure regulator. Water feed pressure must be
between 40‐60 psi. Turn on the water supply and check for leaks.
2.
Check to ensure that the Red Power Switch is off.
O=OFF
3.
Connect the power cord to the back of the
Waterlogic WL200 Water Treatment System
and
to a
120 Volt supply.
4.
Fill the Cold Tank. Hold a container under the dispensing faucet, press and hold the main
dispensing button until a continuous flow of water is obtained. Once a continuous flow is
obtained, release the dispensing button. Cold tank is now full.
5.
Move the
Waterlogic WL200
Water Treatment System
into its final operating position. Be sure
that a minimum of 2” clearance is maintained around both the sides and the back of the unit.
This is important to allow proper airflow and heat exchange of refrigeration system.
6.
Level unit using the adjustable feet to level if necessary. Never install on incline.
7.
Turn the Red Power Switch on.
I=ON
.
8.
When the unit has reached its Cold Temp Set Point Temperature, the compressor will cycle off.
9.
Once the unit is at the target temperature(s), sample the water to ensure water meets
expectations and additional rinsing or adjustment is not required.
10.
Check the unit for any leaks. External Leak Protection is always recommended.