background image

 

WL200

 Manual 

                                                                    Page 38 ‐ Revision: 4‐29‐2019 

 
1.

 

Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.  

Waterlogic

 requires the use of a water pressure regulator.  Water feed pressure must be 

between 40‐60 psi.   Turn on the water supply and check for leaks.   

  

 

2.

 

Check to ensure that the Red Power Switch is off.   

O=OFF

 

 

 
 
 
 

3.

 

Connect the power cord to the back of the 

Waterlogic WL200 Water Treatment System 

and

 to a 

120 Volt supply. 

 

4.

 

Fill the Cold Tank.  Hold a container under the dispensing faucet, press and hold the main 
dispensing button until a continuous flow of water is obtained.  Once a continuous flow is 
obtained, release the dispensing button.  Cold tank is now full.   

 

5.

 

Move the 

Waterlogic WL200

 

Water Treatment System

 

into its final operating position.  Be sure 

that a minimum of 2” clearance is maintained around both the sides and the back of the unit.  
This is important to allow proper airflow and heat exchange of refrigeration system.  

 

6.

 

Level unit using the adjustable feet to level if necessary.  Never install on incline. 

 

7.

 

Turn the Red Power Switch on.  

I=ON

.   

 

 
 
 
 

 

8.

 

When the unit has reached its Cold Temp Set Point Temperature, the compressor will cycle off. 

 

9.

 

Once the unit is at the target temperature(s), sample the water to ensure water meets 
expectations and additional rinsing or adjustment is not required.  

 

 

10.

 

Check the unit for any leaks.  External Leak Protection is always recommended. 

 

 

Summary of Contents for WL200

Page 1: ...he faucet 5 gallon container or drain basin Sanitizer Household Bleach 5 25 Sodium Hypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fitting...

Page 2: ...ith filters Filters should be configured to optimize your system Filters need to be configured and specified to do the job given the local water conditions usage maintenance schedule and placement res...

Page 3: ...atment System 11 Flush the Cold Tank Run several gallons of water through the faucet by dispensing cold water to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips...

Page 4: ...Bleed Water Pressure 1 Isolate the WL200 Water Treatment System from feed water by turning off the supply 2 Dispense cold still water to relieve any pressure built up in the system 3 Remove the water...

Page 5: ...Power Switch to disable the compressor O OFF Turn off Water Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pre...

Page 6: ...from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require...

Page 7: ...ed Once a continuous flow is obtained release the dispensing button Cold tank is now full 5 Move the Waterlogic WL200 Water Treatment System into its final operating position Be sure that a minimum of...

Reviews: