WL200

 TOWER DRAINING INSTRUCTIONS 

 

Draining Notes 
 

Drain the 

WL200

 

Water Treatment System

 for transportation. 

 

       WARNING!

  

STORE AND TRANSPORT UNIT EMPTY. 

  

ALWAYS SANITIZE BEFORE USE. 

The unit must be 

completely drained 

before storing to avoid stagnation and reduce 

microbiological contamination (potential bacterial growth).  Always sanitize before use to 
eliminate any potential microbiological contaminates.

 

 

Disable Cold Tanks 

 

1.

 

Turn off the Red Power Switch to disable the compressor. 

O = OFF

 

 

Turn off Water Supply and Bleed Water Pressure 
 

2.

 

Isolate the unit from feed water by turning off the supply.  

3.

 

Dispense cold still water to relieve any pressure built up in the system. 

4.

 

Remove the water supply line from the inlet line bulkhead fitting at back of machine. 

5.

 

Install dust cap or plug into water supply line bulkhead fitting. 

 

Drain the Cold Water Tank and Circuit 
 

6.

 

Remove lower front panel to access tank feed lines. 
 

                        

 

 

7.

 

Disconnect tank line feed line from cold inlet solenoid to 
drain into basin or catch. 

 

8.

 

Reconnect tubing into inlet elbow once drained.

 

 

9.

 

Dry inside of unit if necessary.   

 

10.

 

Replace lower front panel. 

 

Summary of Contents for WL200

Page 1: ...he faucet 5 gallon container or drain basin Sanitizer Household Bleach 5 25 Sodium Hypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fitting...

Page 2: ...ith filters Filters should be configured to optimize your system Filters need to be configured and specified to do the job given the local water conditions usage maintenance schedule and placement res...

Page 3: ...atment System 11 Flush the Cold Tank Run several gallons of water through the faucet by dispensing cold water to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips...

Page 4: ...Bleed Water Pressure 1 Isolate the WL200 Water Treatment System from feed water by turning off the supply 2 Dispense cold still water to relieve any pressure built up in the system 3 Remove the water...

Page 5: ...Power Switch to disable the compressor O OFF Turn off Water Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pre...

Page 6: ...from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require...

Page 7: ...ed Once a continuous flow is obtained release the dispensing button Cold tank is now full 5 Move the Waterlogic WL200 Water Treatment System into its final operating position Be sure that a minimum of...

Reviews: