                                                                    Page 32 ‐ Revision: 4‐29‐2019 

PRE‐INSTALLATION PROCEDURES 

 

      DANGER!

 

 

ELECTRICAL SHOCK HAZARD.  

Only qualified personnel who have read and understand this entire manual should attempt to 
install, or service this unit, failure to do so could result in death or serious injury.  DO NOT plug 
into an electrical supply until specifically instructed.  

 

 

       WARNING!

  

ALWAYS SANITIZE BEFORE USE. 

 Sanitize before use to eliminate any potential microbiological contaminates.      
 

CAUTION!

  

DRIP TRAY DRAIN.

  

If you intend to provide a drip tray drain for your customer, be aware that you will be called 
multiple times per month to service and unclog the tubing leading away from the drip tray to 
drain.  Users will clog the drain with paper clips, erasers, napkins, tea bags, gum, and various 
other intended items.  Waterlogic recommends you establish a minimum of weekly visits to 
the machine for cleaning of the drip tray drain.

 

 

Materials Needed:  

 

Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  

 

Phillips Screwdriver   

 

Temperature Gage 

 

Water Pitcher or Container to collect water from the faucet 

 

5 gallon container or drain basin 

 

Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 

 

¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings 

 

TDS Meter and Test Strips for measuring chlorine ‐ Optional 

 

1.

 

Unpack the 

Waterlogic WL200 Water Treatment System

 

and check exterior for damage.

 

 

  

 

Sanitizing 

 
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved 
cleaner throughout the cold and sparkling water circuits.  Follow all instructions on the sanitizer 
and flush with fresh water through the faucet until odor and taste is acceptable. 

 

       WARNING!  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

 

Always ensure proper ventilation and use proper personal protective equipment such as gloves 
and eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific 
requirements of each chemical product. Take all necessary precautions to prevent sanitizer 
from contacting eyes, clothing, and any other surfaces in could damage (carpets).  

 

 

2.

 

Put 1 teaspoon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½ 
cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) in the Sanitizing 
Cartridge.  Always ensure sanitizer is compatible with stainless steel and acetyl plastic. 

 

Summary of Contents for WL200

Page 1: ...he faucet 5 gallon container or drain basin Sanitizer Household Bleach 5 25 Sodium Hypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fitting...

Page 2: ...ith filters Filters should be configured to optimize your system Filters need to be configured and specified to do the job given the local water conditions usage maintenance schedule and placement res...

Page 3: ...atment System 11 Flush the Cold Tank Run several gallons of water through the faucet by dispensing cold water to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips...

Page 4: ...Bleed Water Pressure 1 Isolate the WL200 Water Treatment System from feed water by turning off the supply 2 Dispense cold still water to relieve any pressure built up in the system 3 Remove the water...

Page 5: ...Power Switch to disable the compressor O OFF Turn off Water Supply and Bleed Water Pressure 2 Isolate the unit from feed water by turning off the supply 3 Dispense cold still water to relieve any pre...

Page 6: ...from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require...

Page 7: ...ed Once a continuous flow is obtained release the dispensing button Cold tank is now full 5 Move the Waterlogic WL200 Water Treatment System into its final operating position Be sure that a minimum of...

Reviews: