WL100
Manual Page 20 Revision: 1‐14‐2019
PROGRAMMING “DISABLING ENERGY SAVING SLEEP MODE”
All
WL100 Water Treatment Systems
come from the factory with Energy Saving Sleep Mode
engaged to meet the Energy Star Certification requirements. Energy Star Sleep Mode disables
the Heater Circuit if the hot dispense has not been used for 3 hours.
Selecting any button "wakes up" the
WL100 Water Treatment System
and turns the Heater
circuit back on. The Hot Tank will typically take less than 10 minutes to heat the water from
ambient to the 85°C (185°F) set point.
Unplug Power Cord and remove Top Cover to access Energy Saver PCB.
ENERGY SAVING SLEEP MODE
ON
OFF
PCB Jumper JP7 (Pin Numbers 1 and 2)
PCB Jumper JP7 (Pin Numbers 2 and 3)
Energy Saver PCB – PN 20‐0075 – Factory PN EN‐6131
JP7
JP7 PIN NUMBERS
1
2
3
1 2
2 3