3.6
Insert the new UV lamp while holding the
white end caps only. Insert the UV lamp
as shown in the illustration and push it all
the way down until it cannot go
any further
CAUTION
:- Do not use force when removing and
inserting the UV lamp as you may
damage internal parts
:- Do not touch the UV lamp glass
surface with your fingers as this
will affect the performance of the
UV lamp
3.7
Re-connect the UV lamp connector
making sure the connectors are lined
up correctly as they will only fit together
when correctly aligned
3.8
To remove the Filter, do the following:
1. Rotate the red rotating lever so that it is parallel
with the side panel
2. Insert your finger into the round hole of the
lever, and pull the lever up to the
vertical position
3. Pull the lever straight up to remove
the Filter assembly (Slight force may
be required. Support the unit with
your other hand while pulling the
filter out).
Note:
Dispose of the filter
following your local guidelines
1.
2.
3.