WARNING!
HOT WATER. Unit produces Hot Water in excess of 87
o
C (188
o
F).
Water above 52
o
C
(125
o
F) can cause severe burns or scalding. Keep unauthorized people and children away from the
unit to avoid accidental dispensing of hot water.
WARNING!
CONNECT TO POTABLE WATER SUPPLY.
This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
CAUTION!
INDOOR USE ONLY.
Intended for household use only.
Never expose to direct sunlight,
heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F). Install indoors and
keep unit away from excessive humidity. Never expose to freezing temperatures. Ensure there is
adequate clearance around the unit to allow refrigeration system condenser to dissipate heat.
Warmer environments require more clearance around the unit. Minimum clearance around all
surfaces of the machine is 2‐inches. Installs where the ambient temperature exceeds 27°C (80°F),
require a minimum of 4‐inches clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic
will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 40 psi to 60 psi. Be
aware of any potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES.
Feed the unit with a potable ambient or cold water
supply only.
Feed water over 37°C (100°F) can damage the treatment components. Water block
devices and external leak detectors are strongly recommended. Locate the unit as close to the water
supply and the electrical connections as possible. Locate the unit as close to the water supply and
the electrical connections as possible. Immediately isolate or close water supply valve and contact
service representative if leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.