WaterLogic CUBE Quick Start Manual Download Page 2

 

CUBE

 Manual 

                                                                        Page 5 – Revision 10‐8‐2018 

 

 

WARNING!  

HOT WATER.  Unit produces Hot Water in excess of 87

o

C (188

o

F).  

Water above 52

o

(125

o

F) can cause severe burns or scalding.  Keep unauthorized people and children away from the 

unit to avoid accidental dispensing of hot water.    

 

WARNING! 

CONNECT TO POTABLE WATER SUPPLY.

 This system is to be used for water only and is 

not intended for use where water is microbiologically unsafe or with water of unknown quality 
without adequate disinfection before or after the system. 

 

       WARNING!

  

STORE AND TRANSPORT UNIT EMPTY. 

  

ALWAYS SANITIZE BEFORE USE. 

The unit must be completely drained and sealed before storing to avoid stagnation and reduce 
microbiological contamination (potential bacterial growth).  Sanitize before use to eliminate any 
potential microbiological contaminates

 

 

CAUTION!

  

INDOOR USE ONLY.   

Intended for household use only.

  

Never expose to direct sunlight, 

heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F).  Install indoors and 
keep unit away from excessive humidity.  Never expose to freezing temperatures.  Ensure there is 
adequate clearance around the unit to allow refrigeration system condenser to dissipate heat.  
Warmer environments require more clearance around the unit.  Minimum clearance around all 
surfaces of the machine is 2‐inches.  Installs where the ambient temperature exceeds 27°C (80°F), 
require a minimum of 4‐inches clearance for proper heat dissipation and efficient operation.    

 

CAUTION!

  

USE A WATER PRESSURE REGULATOR. Waterlogic

 will not be responsible for injury or 

damage caused by excessive water pressure.  Input or feed pressure must be 40 psi to 60 psi.  Be 
aware of any potential pressure surges caused by building/municipal pumping stations.   

 

CAUTION!

  

USE UV STABILIZED SUPPLY LINES.  

Feed the unit with a potable ambient or cold water 

supply only.

  

Feed water over 37°C (100°F) can damage the treatment components.  Water block 

devices and external leak detectors are strongly recommended. Locate the unit as close to the water 
supply and the electrical connections as possible.  Locate the unit as close to the water supply and 
the electrical connections as possible.  Immediately isolate or close water supply valve and contact 
service representative if leak is noticed. 

 

 
 

Contact Waterlogic for assistance or help finding an Authorized Service Representative.

 

 

 

Summary of Contents for CUBE

Page 1: ...for future use DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly grounded outlet Unit should be protected by ground fault circuit interrupter GFCI or residual current device RCD havin...

Page 2: ...res Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around the unit Minimum clearance around all...

Page 3: ...essed faucet to protect from cross contamination Leak Sensor and Alarm Leak Sensor and Alarm Full Fault Mode that halts supply to prevent overflow and sounds alarm to reduce accident potential Digital...

Page 4: ...al Purifiers The Public Health and Safety Organization establishes minimum requirements for health and sanitation characteristics of microbiological water purifiers The requirements are based on the r...

Page 5: ...0 37 Gallons Cold Tank Hot Water Temperature Factory Set Point 86 C 187 F Programmable 70 95 C 158 203 F Hot Water Capacity 1 3 Liter 0 34 Gallons Hot Tank Extra Hot Water Temperature Factory Set Poi...

Page 6: ...x 560 mm 22 inches x 560 mm 22 inches 8 units per pallet Shipping Weight Dry 19 kg 41 pounds CUBE is 17 inches tall and may not fit between countertops and cabinets Check installation to ensure adequa...

Page 7: ...The delay is a safety feature that prevents hot water from being accidently dispensed Hold Extra Hot Selection until button stops flashing which indicates the temperature has been reached Press and Ho...

Page 8: ...dle of the panel to dispense water 4 Water Selection is dispensed via a Push To Dispense method Press and hold the dispense button until your cup has reached the desired level WARNING Unit produces Ve...

Page 9: ...for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installation and...

Reviews: