CUBE
Manual
Page 28 - Revision: 5-24-2017
UV LAMP REPLACEMENT
1.
Remove the UV Lamp Protective Cover from the front
right hand side of the CUBE by removing the fixing screw
and lifting the cover up
2.
Disconnect the UV Lamp Connector by pressing in the
clip on the side of the machine as shown (#1)
Pull the connector towards the front of the machine (#2)
3.
Firmly pull the old UV Lamp up and out of the CUBE.
Do not pull the lamp out an angle as it may break or
damage the internal parts of the CUBE.
4.
Insert the new UV Lamp while holding the white end
caps only.
Insert the UV Lamp, ensuring you have pushed it all the
way down until it cannot go any further.
Reconnect the UV lamp Connector, making sure the
connectors are lined up correctly as they will only fit
when correctly aligned.
5.
Reinstall the UV Lamp Protective Cover and Secure it in
place with the fixing screw.
6.
Install the Top Cover onto the machine by placing cover
into position. Ensure the two fixing logs at the front are
lined up with the grooves (#1) then pulling the cover
firmly towards yourself until it clicks into place (#2)