Installation
04.12.2015
17 / 48
Copyright
2014 by: WATERKOTTE GmbH. Subject to changes.
6.2
Creating the foundation and installing heat pump
- with best possible structure-borne noise insulation
6.2.1
Laying a foundation for acoustic heat pump
1
Heat pump
2
Noise-absorbent mat Polyethylen (PE)
3
Insulation material (3 layer, polyurethan rubber)
4
Supporting subsurface
5
Insulation material
6
Screed
7
Concrete plinth
Dimensions concrete plinth (mm):
Plinth
Width
x
Depth
x
High
EcoTouch
DS 5050T
850 mm
700 mm
150 mm