2

Congratulations!

You have purchased the finest commercial reverse osmosis water system 

available.  It will provide years of reliable service if properly installed, 

operated and maintained.

  

Please read this entire manual before attempting 

installation and operation.

Section 1.  Frequently Asked Questions

Before getting started, take the time to familiarize yourself with your new Waterite system by 

reading some FAQs listed below.  Call us or ask your dealer if you have any other questions 

about your system’s operation.

Q: How does the Vectapure™ RSX II Reverse Osmosis System differ from an ordinary water 

filter?

Ordinary water filters use a screen to separate only particles of dirt and sediment from the raw water 

source.   Reverse osmosis employs a semi-permeable membrane that removes not only particles 

but also a very high percentage of dissolved contaminants, molecule by molecule, from your raw 

water.  Your system will deliver pure, refined water consistently to the designated storage tank or water 

distribution equipment.

 

 

Q: What is the membrane and how does it work?

The membrane element consists of several thin layers or sheets of film that are bonded together and 

rolled in a spiral configuration around a plastic tube.  As the raw water passes across the surface of 

the membrane, only pure water molecules are allowed to pass through and collect in the tube, while all 

other mineral and contaminant molecules are rejected and washed from the surface of the membrane 

to the drain.

Q: What processes does the Vectapure™ RSX II RO system use? 

Vectapure™ RSX II systems use two stages of treatment to produce high-purity product water.  The 

feed water first flows through a 5-micron polypropylene filter used to reduce suspended particles.  The 

second stage is the reverse osmosis membrane that separates most dissolved contaminants from the 

water molecules.  These standard processes will probably be augmented with additional pre-treatment 

processes, depending on your raw water source.

Q: Will reverse osmosis remove sodium chloride and other salts from the water?

Yes.  Reverse osmosis was originally developed to make drinking water from seawater.   Your system 

is equipped with a membrane that will be very effective in reducing sodium levels normally found 

in ground water or softened water.  

Vectapure™ RSX II systems are not designed for use on 

seawater, or Brackish water with a TDS above 1500ppm

  

Q: Does reverse osmosis remove bacteria? Cryptosporidium? Viruses?

Reverse osmosis membranes will virtually eliminate most chemicals, bacteria, viruses and parasites 

such as Cryptosporidium from the water.  Where these conditions exist, pre-filters and o ther system 

components located before the membrane will become contaminated from exposure to them.  Cross 

contamination of the entire system may occur when the membrane or filters are changed or disturbed.

Summary of Contents for VECTAPURE RSX II

Page 1: ...ERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTIO...

Page 2: ...d to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Vectapure RS...

Page 3: ...r produced 1 Pressure The greater the RO system pressure the greater the water quantity that will be produced by the membrane Your Vectapure RSX II unit has been equipped with ultra low energy membran...

Page 4: ...king water or water analyses indicate a rising TDS it probably means that your membrane s are deteriorating and is losing effectiveness You may purchase a pocket or full featured TDS meter from your d...

Page 5: ...tyrene or polyacrylic regenerated with salt Chlorine Feed water should be free of chlorine 1 ppm as TFC membranes are easily damaged by chronic chlorine exposure This is an important consideration whe...

Page 6: ...permeable membrane The concentrate stream on the other hand contains constituents that have been rejected by the membrane An inherent advantage of crossflow filtration is its ability to continuously o...

Page 7: ...sed salt passage Carbon Filter CF Series Excelclear Carbon pH 5 5 9 5 Internal corrosion Lime scaling in equipment Plumbing damage Replace water source Adjust pH Call your dealer Organic or Microbiolo...

Page 8: ...IDGE IN THE PRE TREATMENT FILTER HOUSINGS SUPPLIED FOR THE PRIMARY REDUCTION OF CHLORINE IT WILL REQUIRE REPLACEMENT TOO OFTEN LIMIT FLOW RATES AND LIKELY LEAD TO CHLORINE BREAKTHROUGH TO THE MEMBRANE...

Page 9: ...h If the inlet bulkhead fitting to the non pressurized tank is below the maximum water level in the tank make sure that a check valve is installed in the product water line between the RO unit s outle...

Page 10: ...Filter Cartridge and Membrane s 1 Remove the filter housing bowl by turning counter clockwise with the housing wrench supplied Remove all protective wrapping from the 5 micron filter cartridge Insert...

Page 11: ...sure that they are in good condition and are secure in their seating grooves While the housing is disassembled clean all components thoroughly to remove any debris or scaling When re assembling make s...

Page 12: ...ntial septic field for receiving the RO waste water from Vectapure RSX II systems unless the field has a rated capacity in excess of the waste flow capacity If used to 24 hour capacity these systems w...

Page 13: ...ded for feed water of less than a TDS of 1000ppm By changing the DLFC the TDS range can be increased up to 2000ppm See spare parts for range and part numbers when ordering an alternate DLFC Make sure...

Page 14: ...PERIOD A Note on Recovery Rates Your Vectapure RSX II is designed to operate at a recovery rate percentage of product water to total water used at maximum of 60 for feed water of 1000 TDS and 35 40 fo...

Page 15: ...system pressure feed water TDS permeate TDS permeate flow rate and waste flow rate This will allow you to see any developing performance trends or alert you to system changes that will require you to...

Page 16: ...parts or repair service during the warranty period Read the document completely for warranty claim instructions Your Vectapure RSX II system comes with a limited one year warranty covering materials...

Page 17: ...housing leaking Tighten with housing wrench Inspect o rings for cuts or crimps Low System Pressure Clogged pre filter or fouled pre treatment Replace pre filter cartridges Low feed water pressure Chec...

Page 18: ...oduct Adapter O ring N70209 Membrane Housing End Cap O ring N70328 Pre Filter Housing O ring RKE0013HLB Black Max 2521 Membrane TFC LP BME2521SL Drive Pump 100 GPH APR3BZ Drive Pump 140 GPH APR4BZ Dri...

Page 19: ...II 350 2 0 USGPM minimum includes 20 safety factor RSX II 700 3 0USGPM minimum on 1000 TDS feed water Feed water must be available at a minimum of 40 psi and a maximum of 80 psi at the specified flow...

Page 20: ...20 Section 10 Vectapure RSX II Performance Log Date Line Pressure System Pressure Permeate TDS Feed Water TDS Pre Filter Change Fast Flush Permeate Flow Meter Waste Flow Meter...

Page 21: ...er Quality Owner Contact Installation Date Phone Serial Dealer Model CATIONS ANIONS Barium Bromide Calcium Chloride Iron Fluoride Potassium Bicarbonate Magnesium Sulphate Manganese Nitrate Sodium Phos...

Page 22: ...22 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Page 23: ...23 REGISTER YOUR PRODUCT ONLINE AT WATERITE COM OR FILL OUT THE INCLUDED PRE PAID SELF ADDRESSED POSTCARD...

Page 24: ...24 Waterite Inc Winnipeg Manitoba Canada www waterite com...

Reviews: